Pilz PMCprimo DriveP.06/AA0/4/0/0/208-480VAC User Manual
Page 39
Function description
Operating Manual PMCprotego S22(C)
1002529EN02
39
Timing diagram:
v
t
Reset
1
0
1
0
1
0
1
0
1
0
SS1 Activate
Ready
STO Acknowledge
SDI
1
0
SDA Safe Direction
Acknowledge
SDI Neg Activate
1
0
SDI Pos Activate
t1
t2
Tolerance window
SDI
SDI delay time
Fig.: Changing the direction of rotation with SDI delay time
}
t
1
: Activation of safety function SDI in negative direction of rotation
}
t
2
: Once the SDI delay time has elapsed, the negative direction of rotation is monitored
}
SS1 Activate: Input for safety function SS1
}
Reset: Input for reset
}
SDI Neg Activate: Input for safety function SDI, anticlockwise rotation is monitored
(new direction of rotation)
}
SDI Pos Activate: Input for safety function SDI, clockwise rotation is monitored (old dir
ection of rotation)
}
Ready: Output for operating status of safety card and second output for feedback from
safety function STO
}
STO Acknowledge: Output for feedback from safety function STO
}
SDA Safe Direction Acknowledge: Output for feedback from safety function SDI
- PMCprimo DriveP.24/ABB/4/0/0/208-480VAC PMCprimo DriveP.06/AB0/2/0/0/208-480VAC PMCprimo DriveP.06/AB0/3/0/0/208-480VAC PMCprimo DriveP.24/AA0/5/0/0/208-480VAC PMCprotego D.06/000/0/0/2/208-480VAC PMCprotego D.24/000/0/0/2/208-480VAC PMCprotego D.06/010/0/0/2/208-480VAC PMCprotego D.06/100/0/0/2/208-480VAC PMCprotego D.06/200/0/0/2/208-480VAC PMCprotego D.24/200/0/0/2/208-480VAC PMCprotego D.24/100/0/0/2/208-480VAC PMCprotego D.24/010/0/0/2/208-480VAC PMCprotego S2-2 PMCprotego S2-2-C