8.4

Messages

Any errors on the safety card are indicated on the servo amplifier display with message
"F31".

The following options are available for detailed diagnostics and fault detection:

}

LEDs on the front of the safety card provide information on operating states (see sec­
tion on "Display elements" in this chapter).

}

Outputs on the safety card display the state of the safety functions (e.g. STO Acknow­
ledge).

}

Errors and messages are entered in the safety card's error stack.

}

The following are displayed in online mode in the Configurator PASconfig SDrive:

Safety card status messages and error messages (error stack)

States of safety card inputs and outputs

Errors and states of inputs and outputs on the motion control system

See also "Servo amplifier configuration software"

}

Errors, messages and the corresponding remedies are displayed in the expanded dia­
gnostics system PVIS.