Function description
Operating Manual PMCprotego S22(C)
1002529EN02
38
}
The SDI delay time can be used to optimise the time taken to switch the direction of ro
tation. The new direction can be activated while the SDI delay time t
m
is running. Only
then is monitoring of the old direction of rotation deactivated (see Case B in the illustra
tion and timing diagram).
NOTICE
Please note that the direction of rotation may only ever be monitored in one
direction. The safety function SS1 will trigger if monitoring in both directions
is activated simultaneously.
v
t
SDI
SDI Neg Activate
SDI Pos Activate
SDI
v
t
SDI
SDI Neg Activate
SDI Pos Activate
SDI
tm
A
B
tm = 0
Fig.: Changing the direction of rotation
This manual is related to the following products:
- PMCprimo DriveP.24/ABB/4/0/0/208-480VAC PMCprimo DriveP.06/AB0/2/0/0/208-480VAC PMCprimo DriveP.06/AB0/3/0/0/208-480VAC PMCprimo DriveP.24/AA0/5/0/0/208-480VAC PMCprotego D.06/000/0/0/2/208-480VAC PMCprotego D.24/000/0/0/2/208-480VAC PMCprotego D.06/010/0/0/2/208-480VAC PMCprotego D.06/100/0/0/2/208-480VAC PMCprotego D.06/200/0/0/2/208-480VAC PMCprotego D.24/200/0/0/2/208-480VAC PMCprotego D.24/100/0/0/2/208-480VAC PMCprotego D.24/010/0/0/2/208-480VAC PMCprotego S2-2 PMCprotego S2-2-C