SS2 when OPMODE = 0 ... 8

}

With the drive­activated safety function "safe stop 2" (SS2), the movement is ultimately
continued.

}

The status of the safety card (SS2 activated) is transmitted to the servo amplifier. As a
result, the information is available to a higher level control system (status word).

}

The transfer of setpoint values from external servo amplifier interfaces (bus system or
analogue input) is disabled.

}

The servo amplifier applies speed­controlled braking with the preset braking ramp until
standstill is achieved.

This status is maintained for as long as safety function SS2 is active.

}

If safety function SS2 is deactivated, the status word is updated.

}

The servo amplifier automatically switches to the OPMODE that was originally set.

}

The transfer of setpoint values from external servo amplifier interfaces (bus system or
analogue input) is once again permitted.

}

When OPMODE = 8, the existing motion block can be continued via the "CONTINUE"
command.

s, v

t

t1

SOS delay time

v (t)

s (t)

SOS

t2

SS2 Activate

1

0

Set value

1

0

1

0

SOS Acknowledge

Braking ramp

Any

Any

v = 0

}

SS2 Activate: Input for safety function SS2

}

SOS Acknowledge: Output for feedback from safety function SOS

}

Setpoint value: Specification of setpoint values

INFORMATION

Further information on the command can be found in the servo amplifier's
online help, on the "Motion Control" CD (file ascii_dd5­protego.chm).
Please also refer to the operating instructions for the servo amplifier.