WARNING!

Electric shock!

Safe electrical isolation must be ensured for the external power supply that
generates the supply voltage. Failure to do so could result in electric shock.
The power supplies must comply with EN 60950­1, 05/2006, EN 61558­2­6,
11/1997.

Connector X30

Pin

Name

Description

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

X30

10

24 V Supply

Supply voltage for digital outputs
(24 V)

21, 22 0 V Supply

Supply voltage for digital outputs
(0 V)

Pins 21 and 22 are linked internally

Connector pin assignment

Supply voltage

L3

10

X30

L1

L2

0 V

21, 22

+24 V

PE

+24 V

XGND

Servo Amplifier

*)

Max. cable length: 30 m

24 V connection isolated
from external power supply,
e.g. with

isolating transformer

Noise suppression filter in­
tegrated within the safety
card

*) Please note the follow­
ing
:

Link X30, Pin 21 or 22 to
XGND on the servo ampli­
fier

Connection

*) XGND:

}

PMCprotego D.01 … D.24:

X4A, Pin 2

}

PMCprotego D.48/D.72: