Chapter 4 Display and Operation|ASDA-B Series

Revision January 2009

4-19

Name

Function

UP and DOWN arrow Key. Pressing the UP and DOWN arrow key can scroll through
and change monitor codes, parameter groups and various parameter settings.

In SAVE (

) mode and WRITE (

) mode, pressing UP and DOWN

arrow key can scroll through and change the memory blocks. In SAVE mode, pressing
UP and DOWN arrow key can select and change the memory file name also.

SET Key. Pressing SET key can enter into the Parameter Setting mode, then display,
select and save parameter groups and various parameter settings. During diagnosis
operation, pressing SET key can execute the function in the last step.
(The parameter settings changes are not effective until the SET key is pressed.)

Function Key. Pressing Function key can enable JOG, Reset, Parameter Read &
Write, Fast Editing, Static Auto-tuning and Dynamic Auto-tuning these functions.

4.2.2 Display Flowchart

Monitor Mode, Parameter Mode and Parameter Setting Mode

1. When the power is applied to the AC servo drive, the digital keypad will execute communication

initial setup for approximately two seconds (9600bps & 7,N,2 Modbus ASCII) first, and then enter

into the monitor mode.

2. In monitor mode, pressing UP or DOWN arrow key can switch monitor parameter code.

3. In monitor mode, pressing MODE key can enter into parameter mode, pressing the SHIFT key

can switch parameter group and pressing UP or DOWN arrow key can change parameter group

code.

4. In parameter mode, system will enter into the parameter setting mode immediately after the SET

key is pressed. The LED display will display the corresponding setting value of this parameter

simultaneously. Then, users can use UP or DOWN arrow key to change parameter value or press

MODE key to exit and return back to the parameter mode.

5. In parameter setting mode, users can move the cursor to left by pressing the SHIFT key and

change the parameter settings (blinking digits) by pressing the UP or DOWN arrow key.

6. After the setting value change is completed, press SET key to save parameter settings or execute

command.

7. When the parameter setting is completed, LED display will show the end code “-END-“ and

automatically return back to parameter mode.