beautypg.com

Delta Electronics ASDA-B Series User Manual

Page 184

background image

Chapter 7 Servo Parameters|ASDA-B Series

Revision January, 2009

7-31

P1 - 26

Reserved

Communication Addr.: 011AH

P1 - 27

Reserved

Communication Addr.: 011BH

P1 - 28

Reserved

Communication Addr.: 011CH

P1 - 29

Reserved

Communication Addr.: 011DH

P1 - 30

Reserved

Communication Addr.: 011EH

P1 - 31

Reserved

Communication Addr.: 011FH

P1 - 32

LSTP

Motor Stop Mode Selection

Communication Addr.: 0120H

Default: 0

Related Section: N/A

Applicable Control Mode: P/S/T

Unit: N/A

Range: 0 ~ 11

Settings: This parameter is used to select servo motor stop mode.

ASD-PU-01A ASD-PU-01B

• Fault Stop Function Settings:

When a fault occurs (except for CWL, CCWL, EMGS and serial communication error), it is
used to set servo motor stop mode.

0: Stop instantly

1: Decelerate to stop

• Dynamic Brake Activation Settings:

When a fault occurs (except for CWL, CCWL, EMGS and serial communication error), the
servo drive will turn on (Servo On) and then off (Servo Off) automatically.

0: Use dynamic brake when Servo Off (the servo drive is disabled).

1: Allow servo motor to coast to stop when Servo Off (the servo drive is disabled).