beautypg.com

4 electromagnetic brake, 4 electromagnetic brake -36 – Delta Electronics ASDA-B Series User Manual

Page 151

background image

Chapter 6 Control Modes of Operation|ASDA-B Series

6-36

Revision January, 2009

When the servo motor runs with load, the allowable frequencies will change according to the changes of

the load inertia and rotation speed. Use the following equation to calculate the allowable frequency.

Allowable fr equency =

Allowable frequency when serv o motor run without load

m + 1

x

Rated s peed

Operating speed

times

mi n.

2

m = load/motor inertia ratio

The users can select the adequate regenerative resistors according to the allowable frequencies by

referring to the table below:

Allowable frequency when the servo motor run without load (times/min)

100W

200W

300W

400W

(60mm)

400W

(80mm)

ECMA Series


Regenerative
Resistors

01

02

03

04

04

BR400W040 - - -

8608

3279

BR1K0W020 - - -

21517

8765

500W

600W

750W

900W

1.0kW

(100 mm)

ECMA Series


Regenerative
Resistors

05

06

07

09

10

BR400W040 291 283 2128 213 925

BR1K0W020 729 708 5274 533 2312

1.0KW

(130mm)

1.5KW

2.0kW

(100mm)

2.0KW

(130mm)

2.0KW

(180mm)

ECMA Series


Regenerative
Resistors

10

15

20

20

20

BR400W040 283 213 562 163 68

BR1K0W020 708 533 1363 408 171

( ) : motor frame size, unit is in millimeters.

Table 6.L

6.6.4 Electromagnetic Brake

When the servo drive is operating, if the digital output BRKR is set to Off, it indicates the

electromagnetic brake is disabled and motor is stop running and locked. If the digital output BRKR is set

to ON, it indicates electromagnetic brake is enabled and motor can run freely.

There are two parameters that affect the electromagnetic brake. One is parameter P1-42 (MBT1) and

the other is parameter P1-43 (MBT2). The users can use these two parameters to set the On and Off

delay time of electromagnetic brake. The electromagnetic brake is usually used in perpendicular axis (Z-

axis) direction to reduce the large energy generated from servo motor. Using electromagnetic brake can

avoid the load may slip since there is no motor holding torque when power is off. Without using

electromagnetic brake may reduce the life of servo motor. To avoid malfunction, the electromagnetic

brake should be activated after servo system is off (Servo Off).