Chapter 7 Servo Parameters|ASDA-B Series

7-46

Revision January, 2009

P2 - 24

DPH

Notch Filter Attenuation Rate
(Resonance Suppression)

Communication Addr.: 0218H

Default: 0

Related Section:

Applicable Control Mode: P/S/T

Section 6.3.7, P2-23

Unit: dB

Unit: Hz

Range: 0 ~ 32

Settings:

0: Disabled

P2 - 25

NLP

Low-pass Filter Time Constant
(Resonance Suppression)

Communication Addr.: 0219H

Default: 20

Related Section:

Applicable Control Mode: P/S/T

Section 6.3.7, P2-32

Unit: 0.1ms

Range: 0 ~ 10000

Settings:

This parameter is used to set low-pass filter time constant of resonance suppression.

0: Disabled

P2 - 26

DST

External Anti-Interference Gain

Communication Addr.: 021AH

Default: 0

Related Section:

Applicable Control Mode: P/S/T

Section 6.3.7, P2-32

Unit: N/A

Range: 0 ~ 511

Settings: