Delta Electronics ASDA-B Series User Manual
Page 216

Chapter 7 Servo Parameters|ASDA-B Series
Revision January, 2009
7-63
P4 - 11
SOF1
Analog Speed Input Drift Adjustment 1
Communication Addr.: 040BH
Default: Factory setting
Related Section:
Applicable Control Mode: P/S/T
P4-10
Unit: N/A
Range: 0 ~ 32767
Settings:
Manual Adjustment Operation:
Set parameter P2-08 to 22 and then change this parameter. This is an auxiliary adjusting
function, although this parameter allows the users can execute manual adjustment, we still do
not recommend users to change the default setting manually.
Auto Adjustment Operation:
Set parameter P2-08 to 20 first and then set parameter P4-10 to 1.
When executing this auto adjustment, ensure that the external wiring connected to analog speed
must be removed or an external zero voltage power is applied to the servo drive from the host
controller and the servo system should be off (Servo off).
NOTE
1) When P2-08 is set to 10, users cannot reset this parameter.
P4 - 12
SOF2
Analog Speed Input Drift Adjustment 2
Communication Addr.: 040CH
Default: Factory setting
Related Section:
Applicable Control Mode: P/S/T
P4-10
Unit: N/A
Range: 0 ~ 32767
Settings:
Please see P4-11 for explanation.
NOTE
1) When P2-08 is set to 10, users cannot reset this parameter.
P4 - 13
TOF1
Analog Torque Drift Adjustment 1
Communication Addr.: 040DH
Default: Factory setting
Related Section:
Applicable Control Mode: P/S/T
P4-10
Unit: N/A
Range: 0 ~ 32767
Settings:
Manual Adjustment Operation:
Set parameter P2-08 to 22 and then change this parameter. This is an auxiliary adjusting