beautypg.com

Configure[1..n]:analysis:threshold: reflectance – EXFO FTB-7000 OTDR Series for FTB-500 User Manual

Page 405

background image

SCPI Command Reference

OTDR

391

Product-Specific Commands—Description

:CONFigure[1..n]:ANAlysis:THReshold:

REFLectance

Description

This command sets the reflectance threshold

that will be used for the next acquisition.

*RST returns this setting to default value.

Syntax

:CONFigure[1..n]:ANAlysis:THReshold:REFLecta

nce|MAXimum|MINimu

m|DEFault

Parameter(s)

Reflectance:
The program data syntax for is

defined as a element. The

special forms MINimum,

MAXimum and DEFault are accepted on input.

MINimum allows to set the instrument to the

smallest supported value.

MAXimum allows to set the instrument to the

greatest supported value.

DEFault allows the instrument to select a value

for the parameter.

Sets the reflectance threshold.

Example(s)

CONF:ANA:THR:REFL? Ex.: Returns -72.0

CONF:ANA:THR:REFL -72.5

CONF:ANA:THR:REFL? Returns -72.5