beautypg.com

Calculate[1..n]:event – EXFO FTB-7000 OTDR Series for FTB-500 User Manual

Page 339

background image

SCPI Command Reference

OTDR

325

Product-Specific Commands—Description

Response(s)

Event:
The response data syntax for is defined

as a

RESPONSE DATA> element.

Returns the event from the event table

corresponding to the specified trace index.

Event structure is in A, B, C, D, E format, where:

A = Location (always in meters)

RESPONSE DATA>

B = EventType

DATA>

C = Loss (always in dB)

RESPONSE DATA>

D = Reflectance (always in dB)

RESPONSE DATA>

E = Cumulative (always in dB)

RESPONSE DATA>

Here is the list of all possible event types:

1 = Positive splice

2 = Negative splice

3 = Reflection

4 = End of analysis

:CALCulate[1..n]:EVENt?