Description of Event Types

OTDR

305

Pass/Fail Tests

All Event Types Are Tested

In the first case, where all event types are tested, the pass/fail conditions
are as follows:

³

If the event loss is less than or equal to the smallest threshold value,
then the event status is Pass.

³

If the event loss is greater than the sum of the number of sub-events of
a type, multiplied by the threshold value for this event type, then the
event status is Fail.

³

If the event loss is “in between”, since it is not possible to know exactly
the weight of a sub-event in the merged event, the global event is
considered to have a status of Pass.

If the merged event loss is smaller than or equal to 1.2, then the status is
Pass. Otherwise, it is Fail.

Pass/Fail Analysis

Fail Level
=

Σ

(N

sub

x Th

sub

)

= (2 x 0.5) + (1 x 0.2)
= 1.2

Pass

Pass

Fail

0

0.2

1.2