beautypg.com

See :configure[1..n]:analysis, Iorefraction, Configure[1..n]:analysis: iorefraction – EXFO FTB-7000 OTDR Series for FTB-500 User Manual

Page 399

background image

SCPI Command Reference

OTDR

385

Product-Specific Commands—Description

:CONFigure[1..n]:ANAlysis:

IORefraction

Description

This command sets the index of refraction that

will be used for the next acquisition.

*RST reverts this setting to default value.

Syntax

:CONFigure[1..n]:ANAlysis:IORefraction

|MAXimum|MINimum|DEFault

Parameter(s)

IOR:
The program data syntax for is defined as

a element. The

special forms MINimum, MAXimum and DEFault

are accepted on input.

MINimum allows to set the instrument to the

smallest supported value.

MAXimum allows to set the instrument to the

greatest supported value.

DEFault allows the instrument to select a value

for the parameter.

Sets the index of refraction.

Example(s)

CONF:ANA:IOR? Ex.: Returns 1.4677

CONF:ANA:IOR 1.5

CONF:ANA:IOR? Returns 1.5