beautypg.com

Setting optical switch parameters, Mportant – EXFO FTB-7000 OTDR Series for FTB-500 User Manual

Page 102

background image

Testing Fibers in Advanced Mode

88

OTDR

Setting Optical Switch Parameters

Setting Optical Switch Parameters

You can configure your switch to use any combination of channels in the
desired order (for example, channel 2, then 4, then 1 will be tested). It is
always possible to reset the order to the default value (channel 1, then 2,
then 3, and so on). You can test with a switch in Advanced mode only.

To set the channel configuration:
1.
From the main window, press Setup.

2. From the Setup window, go to the Automation tab.

3. From the Switch box, select the desired switch (press the arrow next to

the box to view the available switches).

Note: If you no longer want to use a switch in your test, simply select None.

I

MPORTANT

The application can only use switches whose type matches the fiber
type (singlemode or multimode). To test both singlemode and
multimode fibers, you will need two different switches.

I

MPORTANT

To avoid heavy losses in multimode testing, the switch must also
match the core of the fiber under test (50 μm or 62.5 μm).