Checking cylinder head distortion (continued), Valve guide replacement – Generac 86640 User Manual
Page 34
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Checking Cylinder Head Distortion (Con
tinued)
Valve Guide Clearance
Use a suitable dial indicator to measure valve stem to
guide clearance. The valve should be moved parallel to the
rocker arm, since most of the wear occurs in this direction.
See Figure 24.
Figure 24. Valve Guide Clearance
Stem to guide clearance:
Maximum limit
0.10 mm (0.0039 in)
Max. allowable deflection
(Dial indicator readirrgi
0.2 mm (0.008 in)
Valve Guide Replacement
If valve guides must be replaced, proceed as follows:
1. Heat the cylinder head to 302‘-320‘ F. (150‘-160' C.) in an
oil bath (Figure 25).
2. Use a press exerting a 2.2 U.S. ton (20 kN) force to remove
valve guides. If a press is not available, use a hammer and a
suitabfe driving tool (Figure 26).
3. Ream the cylinder head's valve guide hole (Figure 27).
Page 2.3-2
- NP-50LPG (32 pages)
- 004692-0 (44 pages)
- 004707-0 (56 pages)
- 005030-0 (15kW) (60 pages)
- 004475-0 (52 pages)
- 004189-1 (60 pages)
- Generator (16 pages)
- 00941-4 (52 pages)
- 1019-3 (24 pages)
- PRIMEPACT 50 05754-0 (60 pages)
- 04077-1 (32 pages)
- 7500 (20 pages)
- 11400 (16 pages)
- 09290-4 (52 pages)
- DUARDIAN 04079-2 (44 pages)
- 005031-0 (60 pages)
- Guardian Series Standby Gas Engine Generators 005884-1 (4 pages)
- Liquid-Cooled Engine Generator Sets 50Hz (5 pages)
- 004917-5 (48 pages)
- 04390-0 (60 pages)
- 5500EXL (20 pages)
- QT080 (6 pages)
- 005308-0 (48 pages)
- ASPAS1CCL015 (48 pages)
- Guardian Series Standby Generators QT060 (6 pages)
- Guardian Series Residential Standby Generators Air Cooled Gase Engine 005884-1 (5 pages)
- 04675-3 (56 pages)
- 0046265 (64 pages)
- 190/220 (24 pages)
- 005262-0 (56 pages)
- STANDBY GENERATORS 005520-1 (4 pages)
- SVP5000 97193 (16 pages)
- GP 3250 Portable Generator 005982-0 (20 pages)
- 00941-3 (52 pages)
- 004913-2 (52 pages)
- 20kW (52 pages)
- 004626-2 (64 pages)
- 04164-1 (64 pages)
- 004582 (39 pages)
- 005031-2 (56 pages)
- 004692-2 (52 pages)
- QT030 (4 pages)
- Standby Generator QT022 (6 pages)
- Gn - 410 (24 pages)
- XG8000E 5847-0 (2 pages)