Section 10.1- remote start-stop panels, General, Model 9042 remote panel – Generac 86640 User Manual
Page 101: Description, Generac, Generator, Mounting, Connections
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Section 10.1- REMOTE START-STOP PANELS
General
Remote start-stop panels are available which, when
properly installed and connected, allow the engine-generator
to be started and stopped from a convenient remote location.
Several different remote panel models are available. Wiring
harnesses are also available which permit quick interconnec
tion of the panel with the generator. The following remote
panels and wiring harnesses are available;
1. Model 9042 is a remote start-stop panel for gas
generators. The panel mounts (a) a rocker type start-stop
switch, and (b) a "Generator Run" advisory lamp.
2. Model 9043 is a remote panel for gas units that
includes (a) a start-stop switch, (b) a "Generator Run" lamp,
and (c) an hourmeter.
3. Model 9045 is a 10 foot long, 4-wire wiring harness
that may be used to interconnect the Model 9042 and 9043
remote panels with the generator set.
4. Model 9046 is a 30 foot long, 4-wire wiring harness
that may be used to interconnect the Models 9042 and 9043
remote panels with the generator.
5. Model 9060 is a remote gauge panel for use with gas
engine generators. The remote gauge panel is discussed in
Section 10.2.
Model 9042 Remote Panel
DESCRIPTION:
The Model 9042 remote panel is shown in Figure 1,
below.
Figure 2. Model 9042 Cutout Dimensions
-i
-©
Figure 1. Model 9042 Remote Start-Stop Panel
GENERAC
n.v.
GENERATOR
Figure 3. Generator’s Remote Panel Receptacle
WIRE #14
(ENGINE RUN SIGNAL)
WIRE #0
(GROUND)
WIRE
#17
(CRANK)
MOUNTING:
The Model 9042 panel is designed for flush mounting to
a wall or partition. Cutout .dimensions for mounting the panel
are shown in Figure 2.
CONNECTIONS:
A receptacle Is provided on the generator for connection
of the wiring harness. See Figure 3. Figure 4 is a connection
diagram for the remote panel.