Function/Routine
Name
Description
Input
Output
File Name
normalize()
puts a register into normal
form, in which the major
count of Wh is greater than
or equal to zero, and less
than 1,000,000,000. The
minor count of ce counts
(e.g. from w0sum) is made
to be less than 1 Wh and
positive, by transfering
larger amounts into the
major count.
uint8x_t *register_ptr
none
math.c
operating_lcd ()
Displays the number of
hours of operation.
void void rtc.c
OperatingHours()
Calculates hours of
operation from the last valid
mark.
none int32_t
hours
rtc.c
OSCOPE_INIT
Defines DIO_7, the VAR
pulse output as a DIO.
n/a n/a oscope.h
OSCOPE_ONE
Set DIO_7, the same pin as
the VARh pulse output, to
high.
n/a n/a oscope.h
OSCOPE_TOGGLE
Inverts DIO_7, the same pin
as the VARh pulse output.
n/a n/a oscope.h
OSCOPE_ZERO
Set DIO_7, the same pin as
the VARh pulse output, to
low.
n/a n/a oscope.h
pcnt_accumulate()
Accumulates counts from
the previous second.
void void pcnt.c
pcnt_init ()
Initialize logic to count
output pulses.
void void pcnt.c
pcnt_lcd()
Display pulse count on LCD
uint8_t select
void
pcnt.c
pcnt_start()
Starts plse-counting for a
fixed number of seconds.
int16_t seconds
void
pcnt.c
pcnt_update()
Synchronizes pulse counts
with noninterrupting code.
void void pcnt.c
phase_angle_lcd ()
Displays a V/I phase angle.
uint8_t phase
void
phase_angle.c
psoft_init ()
Initializes software pulse
outputs.
void void psoft.c
psoft_out()
Generates two additional
pulse outputs. Call from
ce_busy_isr
void void psoft.c