Sqsum v lsb 0 2, Sqsum i 1 2, Nvbat – Maxim Integrated 71M6521BE Energy Meter IC Family Software User Manual
Page 76
71M652X Software User’s Guide
Revision 1.7
TERIDIAN Proprietary
76 of 138
© Copyright 2005-2007 TERIDIAN Semiconductor Corporation
Name
Purpose
Function or LSB Value
CLI
Format
L in
bits
XDATA
Ical
Current value to be
used for autocalibra-
tion**
Nominal RMS current applied to
all elements during auto-calibra-
tion (LSB = 0.1V). Power factor
must be 1.
)11 unsigned 16 0x0023
VThrshld
Voltage at which to
measure frequency,
zero crossing, etc.
SQSUM
V
LSB
0
2
16
=
This feature is approximated using
the CE’s sag detection.)
)12 unsigned 16 0x0025
PulseWidth
Maximum time pulse
is on.
t = (2*PulseWidth + 1)*397µs,
0xFF disables this feature. Takes
effect only at start-up.
)13 signed 16 0x0029
temp_nom Nominal
tempera-
ture, the temperature
at which calibration
occurs.
Units of TEMP_RAW, from CE.
The value read from the CE must
be entered at this address.
)14 unsigned 32 0x002B
ImaxB Scaling
maximum
current for PCB ele-
ment B, equivalent to
176mV at the IA pin
0.1A )15
unsigned
16
0x002F
IThrshldB Starting
current,
element B
SQSUM
I1
2
16
)16 unsigned 32 0x0031
VBatMin* Minimum
battery
voltage.
Same as VBAT, below
)17
unsigned
32
0x0035
CalCount
Count of calibrations
Counts the number of times
calibration is saved, to a
maximum of 255
)18 unsigned 8 0x0039
RTC copy
Nonvolatile copy of
the most recent time
the RTC was read.
Sec, Min, Hr, Day, Date, Month,
Year
)19
1A
1B
1C
1D
1E
1F
unsigned 8
8
8
8
8
8
8
0x163
deltaT Difference
between
raw temperature and
temp_nom
Same units as TEMP_RAW
)20
signed
32
0x003B
Frequency*
Frequency
Units from CE.
)21
unsigned
32
0x003F
VBAT* Last
measured
battery voltage*
9
2
ADC
n
VBAT
=
ADC counts, logically shifted right
by 9 bits. Note: battery voltage is
measured once per day, except
when it is being displayed or
requested with the BT command.
)22 unsigned 32 0x0043