Maxim Integrated 71M6521BE Energy Meter IC Family Software User Manual
Page 43

71M652X Software User’s Guide
Revision 1.7
TERIDIAN Proprietary
43 of 138
© Copyright 2005-2007 TERIDIAN Semiconductor Corporation
Feature
Code
Size
8KB
16KB
32KB
Description
Wh equation 1
0.2KB
N N/opt
N/opt
Wh equation 2
0.2KB
N/opt N/opt N/opt
Frequency
register
0.1KB
N
Y
Y
Inhibited if freq > 70Hz or voltage is below the
threshold
Wh net metering
0.4KB
N
N/opt
Y
Used only for automatic calibration. No display is
provided.
Wh export register 0.25KB
N
N/opt N/opt
Wh
exported, display reads “3 999999”
Wh export pulse
output
0.25KB N N/opt N/opt
Wh exported, display reads “3 999999”
VARh register
0.1KB
N
N/opt
Y
For autocalibration, and power factor calculation,
signed (net metering).
VARh pulse
output
0.25KB N N/opt Y
VARh import
register
0.4KB N N/opt Y
VARh import
pulse output
0.25KB N N/opt Y
VARh export
register
0.4KB N N/opt Y
VARh export
pulse output
0.25KB N N/opt Y
Operating hours
register
0.36KB N N/opt N/opt
“5
99999.9” Nonvolatile count of tenths of hours of
powered operation since first cold start.
RCT time register 0.18KB
N/opt
Y
Y
RCT date register 0.21KB
N/opt
Y
Y
Pulse source
selection
0.4KB
N
N/opt
Y
This is the ability to route most calculated energy
values to a pulse output. The 8K code provides only
Wh pulses.
Dual IMAX
registers
0.2KB
Y
Y
Y
IMAX2 adjusts current, Wh and VARh from channel B
to same units as A. Creep thresholds are required,
but need not be adjusted when IMAX2 changes.
RMS current
register
0.2KB
N
N/opt
Y
Implemented for two phases “P”, 1 & 2 “1.P 000.000”
RMS voltage
register
0.2KB
N
N/opt
Y
Implemented for two phases “P”, 1 & 2 “1.P 000.000”
Power factor
register
0.3KB N N/opt N/opt
Two
phases are displayed with sign. Reset at reset
and the start of each minute. Volatile.
Table 5-6: Power Registers and Pulse Output Features