Interlogix Monitor XL Advanced Installation Guide User Manual
Page 68
62
Monitor xL™ Advanced Installation Guide
21-3602E rev1.5
(CID codes--continued from preceding page)
E354
UX0
Digital Dialer Comms Failure (Messages Lost), or; Emergency
RO
Misc Trouble (E015)
Emergency
E356
UX1
Security IP Comms Failure (Messages Lost, Sync Lost, Reset)
Emergency
E380
FT
Fire Class A--Tamper, or; Emergency
FT
Fire--Tamper, or; Emergency
PT
Holdup--Tamper, or; Emergency
MT
Aux. Alert--Tamper, or; Emergency
QT
Vault/Safe--Tamper, or; Emergency
UT
Misc/No Type--Tamper, or; Emergency
RB
Module Program Changed (E013), or; Emergency
E383
BT
Burglary --Tamper
Emergency
E384
XT
Module Battery Low--e.g. wireless transmitter (E012)
Emergency
E401
OP
Turn Area Off
Full
E404
JR
Schedule resumed (Stay opened resume)
Emergency
E405
CE
Work late (Closing extended)
Emergency
E409
OA
Automatic Area Off (SDC5 type points)
Full
E422
DG
Second User Authority Granted for Dual Custody
Full
E450
OR
Unauthorized Off (schedules)
Emergency
E451
OK
Emergency Off (schedules)
Emergency
E453
CI
Fail to Turn Area On (Fail to Close)
Emergency
E458
DU
Verify User
Emergency
E459
JS
Schedule suspended (Stay opened suspended)
Emergency
E602
UX2
Digital Dialer Comms Test
Emergency
E607
TS
Walk or Holdup Test Started (no msg at end of test)
Emergency
E625
JT
Time Changed (E007)
Emergency
R100
MR
Aux. Alert--Restore
Emergency
R110
FR
Fire or Fire-Class A--Restore
Emergency
R120
PR
Holdup--Restore Emergency
R120 or PR with event code
“199” for Monitor ISM and
“299” for Monitor xL
Global Lockout Alarm Restore (caused by invalid card/PIN use in Area).
Emergency
R130
BR
Burglary --Restore
Emergency
R140
QR
Vault/Safe--Restore Emergency
R143
ER
Module tamper/comms/subst'n (E011--Restore)
Emergency
R145
RS
Module Program Error (E014--Restore)
Emergency
R150
UR
Misc/No Type--Restore
Emergency
R300
TR
Main panel Tamper (E001--Restore)
Emergency
R301
AR
AC Trouble (E003--Restore)
Emergency
R306
LX
Main panel Config Changed (E008--Restore)
Emergency
R309
YR
No/Low battery (E002--Restore)
Emergency
R320
YQ
Main panel Fuse Failure (E010--Restore)
Emergency
R330
LS
Main panel Program Error (E009--Restore)
Emergency
R333
YK
Security IP Comms Trouble (E016--Restore) Emergency
R351
LR
Phone Trouble (E004--Restore)
Emergency
R354
RC
Misc Trouble (E015--Restore)
Emergency
R380
RN
Module Program Changed (E013--Restore)
Emergency
R384
XR
Module Battery Low--e.g. wireless transmitter (E012--Restore)
Emergency
R401
CL
Turn Area On (Normal)
Full
R402
CF
Turn Area On (Bypass or Forced)
Full
R403
CA
Automatic Area On (Sched. auto-arm on fail to close)
Full
R407
NK+
Emergency Stay Out of Schedule
Emergency
R408
NL
Turn Area to Stay (Normal)
Full
R441
OG
Turn Area to Stay from On
Full
R456
NF
Turn Area to Stay (Bypass or Forced)
Full
R457
NR+
Unauthorized Stay If No Emergency Off
Emergency