Save s004 – Interlogix Monitor XL Advanced Installation Guide User Manual
Page 17
21-3602E rev1.5
Monitor xL™ Advanced Installation Guide
11
S00400 Secondary Card Format—Site Code Checking
WARNING: S004
00
–
S004
05
Access Control related
selections are only available with the addition of
the “Feature Expansion Board”.
Keypad Selections
(left to right on keypad screen) Example:
Default Name
Selections
Description
(no)
Check for Site
Code
(yes)
□
(no)
Whether or not secondary-format tokens must have a specific
site code to be granted entry.
02
Site Code
Position
1 – 40
The position of the 1st digit for the site/system code on these
access tokens.
Position value changes depending on site code length.
08
Site Code
Length
1 – 16
The length of the site code for secondary-format tokens (number
of digits).
Site code when represented as a digital #. Can
not exceed 4 digits.
S00401 Secondary Card Format—Site Codes
Keypad Selections (left to right on keypad screen)
Default Name
Selections
Description
0000
1st Site Code
Value
0000 – 9999
The 1st of up to three site/system
codes that can be encoded within
access tokens to be used at the site.
0000
2nd Site Code
Value
0000 – 9999
The 2nd of up to three site/system
codes that can be encoded within
access tokens to be used at the site.
0000
3rd Site Code
Value
0000 – 9999
The 3rd of up to three site/system
codes that can be encoded within
access tokens to be used at the site.
If site code checking is enabled for a secondary card/token format, cards encoded with any one of up to three site code values can be used at the
site. (All other cards will be globally denied access.)
S00402 Card Version-Information (Secondary)
Keypad Selections (left to right on keypad screen)
Default Name
Selections
Description
(no)
Check for
Version No.
(yes)
□
(no)
Whether or not secondary-format
tokens will be checked for a current
version number.
02
Version No.
Position
1 – 40
The position of the 1st digit for the
version number on these access
tokens.
04
Version No.
Length
1 – 8
The length of the version number for
secondary-format tokens (number of
digits).
This feature requires V1.5 door/elevator controller firmware.
·
02·08
···········
Save S004
00