Monitor xL™ Advanced Installation Guide
21-3602E rev1.5
A0xx02 Keypad Selections
Note: “xx” represents the area number.
(left to right on keypad screen) Example:
Default Name
Selections
Description
0
Exit Delay Warning
Type
0 = Normal, 1=
Warning tone during
Exit Delay, 2=
Warning continuous
3= Warning
continuous + Block
arming
(UK ACPO, European =3)
2
Pre-Alarm Delay
0=20sec; 1=30s;
2=60s; 3=5min;
4=10m; 5=30m;
6=1hr; 7=1.5hrs
During the delay, keypad sonalert(s) will be sounded, giving
an authorized user time to "Silence" the alarm at a keypad.
(Selecting "Verify User" will cancel the alarm transmission.)
Note: This setting works only with sensors (input-points)
that support "Pre-Alarm Warning". For details, refer to
"T080 – T099 (Custom Input-Point Types)".
0
Report Mode
0 = Emergency
1= Full Reporting
System signals transmitted by system dialer to monitoring
station.
0
Siren Squawk on
Arming
0 = Normal, 1=On
Arming, 2 = Fail to
Arm, 3 = On Arming
Or Fail to Arm
The 'siren' outputs for this area will be pulsed briefly when
the area is armed to indicate arming was successful.
(UK ACPO, European =2)
(no)
Function Key PIN
Required
(yes)
□
(no)
Whether a user with "Function Key" authority will need
to log in to use programmable function-keys 6
–
9 & 0.
(no)
Dual Custody
(yes)
□
(no)
Two valid user ID / PINs needed to disarm this area.
(no)
Open Inter-lock Area
(yes)
□
(no)
For all areas set to Yes, only one area can be
disarmed at a time.
(no)
Auto Arm on Door
Close
(yes)
□
(no)
Area will arm when any door closes (used with a bank
vault door).
(no)
Suite Security Area
(yes)
□
(no)
0
·
2
·
0
·
0
·
···
Save A001
02