Monitor xL™ Advanced Installation Guide
21-3602E rev1.5
Default System Programmable Outputs
North America
Output # / Location
Default Codes / Setting
Meaning / Operation
B001:0 (motherboard)
B001:1
“? S000.07 Query ”
“T 000 Timer ”
- Follows Alarm Siren
- Follow (Normal)
B002:0 (motherboard)
B002:1
“? S000.05 Query ”
“T 000 Timer ”
- When system is IN ALARM.
- Follow (Normal)
B003:0 (keypad)
B003:1
“? A001.01 Query ”
“T 005 Timer ”
- Function Key 1 on Area 1 1
st
keypad.
- Positive trigger, 10 sec delay.
B004 - B128
“? 0000.00 Undef ”
“T 000 Timer ”
- Undefined output
- Follow (Normal)
UK
Output # / Location
Default Codes / Setting
Meaning / Operation
B001:0 (motherboard)
B001:1
“? S000.66 Query ”
“T 100 Timer ”
- ACPO Siren
B002:0 (motherboard)
B002:1
“? S000.67 Query ”
“T 100 Timer ”
- Confirmed Alarm (ACPO strobe)
B003:0 (keypad)
B003:1
“? A001.33 Query ”
“T 000 Timer ”
- When area Entry / Exit delay is in progress – provides a steady
output (STAY & ON).
B004:0 (WW STU)
“? S000.60 Query ”
“T 100 Timer ”
- Personal ACPO Attack
B005:0 (WW STU)
“? S000.61 Query ”
“T 100 Timer ”
ACPO Unconfirmed Alarm
B006:0 (WW STU)
“? S000.62 Query ”
“T 100 Timer ”
ACPO Area Set / Unset
B007:0 (WW STU)
“? S000.64 Query ”
“T 100 Timer ”
Bypass in Effect
B008:0 (WW STU)
“? S000.54 Query ”
“T 100 Timer ”
Local AC (mains) failure.
B009:0 (WW STU)
“? S000.65 Query ”
“T 100 Timer ”
ACPO Confirmed Alarm
B010:0 (WW STU)
“? A001.32 Query ”
“T 100 Timer ”
Area is in ‘Walk’ or ‘Hold-up’ test.
Timer Delay Codes (
Bxxx:1)
00: output
default;
01: 1 sec;
02: 2 sec;
03: 3 sec;
04: 5 sec;
05: 10 sec;
06: 15 sec;
07: 20 sec;
08: 30 sec;
09: 45 sec;
10: 60 sec;
11: 90 sec;
12: 2 min;
13: 3 min;
14: 5 min;
15: 10 min;
16: 15 min;
17: 20 min;
18: 30 min;
19: 45 min;
20: 60 min;
21: 90 min;
22: 2 hr;
23: 4 hr;
24: 6 hr;
25: 8 hr;
26: 10 hr;
27: 12 hr;
28: 16 hr;
29: 20 hr;
30: 1 day;
31: 1 week
Specialty
Entries:
98 = toggle
99 = output off