Save s005 – Interlogix Monitor XL Advanced Installation Guide User Manual
Page 19
21-3602E rev1.5
Monitor xL™ Advanced Installation Guide
13
S00500 Dialer Selections
Keypad Selections
(left to right on keypad screen) Example:
Default Name
Selections
Description
000000 Dialer
Account
Number
(Primary)
The system’s monitoring station receiver
number that will identify the premises.
1
Telco Modem
Type
1 = Bell 103, 2 = 8OP STU, 3 = WWMODEM
4 = WWMODEM 8OP STU
STU = Subscriber Terminal Unit
WW = World Wide
(UK ACPO = 2)
(European = 3)
0
Telco Alarm
Report Mode
0 = not used, 1 = primary, 2 = backup, 3 = dual
4 = future
NOTE: “0” turns dialer off and clears all
the messages in the buffer
0
Telco Format
0 = SIA Level 2, 1 = CID, 2 = SIA Level 3
(future), 3 = Future
0
Telco
Sequence
0: ULC
1: UL compatible
2: Long
3: MONITOR Standard
(in Canada use 0 or 3)
Call Sequence Details: (P = Primary phone
# attempt; B = Backup phone # attempt)
0 (ULC): PPBBPPBB / delay 60 min /
PPBBPPBB / delay 60 min / PPBBPPBB /
delay 60 min / PPBBPPBB.
1 (UL): PPBBPPBBPB / delay 10 min.
2 (Long): PPPPBBBB / delay 10 min /
PPPPBBBB / delay 30 min / PPPPBBBB /
delay 60 min / PPPPBBBB /
delay 2 hours / PPPPBBBB.
3 (MONITOR Standard): PPBP / delay 5
min / PPBP / delay 10 min / PPBP / delay
30 min / PPBP / delay 60 min / PPBP /
delay 2 hours / PPBP.
(no)
Telco –
prioritized
reporting
(yes)
□
(no)
(yes) Telco – never
allow blind
dialing
(yes)
□
(no)
Dials regardless of detecting a dial
tone.
(UK ACPO = yes)
Telco = Telephone Company
S00501 Keypad Selections (left to right on keypad screen)
Default Name
Selections
Description
Blank
(16 characters)
Primary Phone Number
–
First Monitoring Station phone number the system will
dial to transmit reports.
The phone number can be preceded with P =pulse dialing (default), or T
=Tone dialing, and can include D =2 sec Delay, A =Star key (tone
dialing), # = Pound Sign (tone dialing), and/or W = Wait for second dial
tone. For Tone dialing, ensure the phone line supports this.
S00502 Keypad Selections (left to right on keypad screen)
Default Name
Selections
Description
Blank
(16 characters)
Secondary Phone
Number
–
Second Monitoring Station phone number the system will
dial to transmit reports, if dialing the primary phone
number is unsuccessful.
The phone number can be preceded with P =pulse dialing (default), or T
=Tone dialing, and can include D =2 sec Delay, A =Star key (tone
dialing), # = Pound Sign (tone dialing), and/or W = Wait for second dial
tone. For Tone dialing, ensure the phone line supports this.
000000
·
1
·
0
·
0
·
0
Save S005