beautypg.com

Event message reference: sorted by cid code – Interlogix Monitor XL Advanced Installation Guide User Manual

Page 67

background image

21-3602E rev1.5

Monitor xL™ Advanced Installation Guide

61

(SIA codes--continued from preceding page)

RB

E380

Module Program Changed (E013)

Emergency

RC

R354

Misc Trouble (E015--Restore)

Emergency

ri

n/a

Area-number reference

Emergency

RN

R380

Module Program Changed (E013--Restore)

Emergency

RO

E354

Misc Trouble (E015)

Emergency

RR

E305

Time Lost (E006)

Emergency

RS

R145

Module Program Error (E014--Restore)

Emergency

RU

E145

Module Program Error (E014)

Emergency

TA

E300

Main panel Tamper (E001)

Emergency

TR

R300

Main panel Tamper (E001--Restore)

Emergency

TS

E607

Walk or Holdup Test Started (no msg at end of test)

Emergency

UA

E150

Misc/No Type

Emergency

UR

R150

Misc/No Type--Restore

Emergency

UT

E380

Misc/No Type--Tamper

Emergency

UX0

E354

Digital Dialer Comms Failure (Messages Lost)

Emergency

UX1

E356

Security IP Comms Failure (Messages Lost, Sync Lost, Reset)

Emergency

UX2

E602

Digital Dialer Comms Test

Emergency

XR

R384

Module Battery Low--e.g. wireless xmitr (E012--Restore)

Emergency

XT

E384

Module Battery Low--e.g. wireless transmitter (E012)

Emergency

YC

E333

Security IP Comms Trouble (E016)

Emergency

YK

R333

Security IP Comms Trouble (E016--Restore)

Emergency

YM

E309

No battery (E002)

Emergency

YP

E320

Main panel Fuse Failure (E010)

Emergency

YQ

R320

Main panel Fuse Failure (E010--Restore) Emergency

YR

R309

No or low battery (E002--Restore)

Emergency

YS

E350

Report Delayed, dialer comms trouble (E005)

Emergency

YT

E302

Low Battery (E002)

Emergency

Event Message Reference: Sorted by CID Code

CID

SIA equiv.

Description / Meaning

Level

E100

MA

Aux. Alert

Emergency

E110

FA

Fire or Fire Class A

Emergency

E120

PA

Holdup Emergency

E120 or PA with event
code “199” for Monitor ISM
and “299” for Monitor xL

Global Lockout Alarm caused by invalid card/PIN use in Area.

Emergency

E121

HA

Duress Pin

Emergency

E130

BA

Burglary Emergency

E134

EE

Fail to Exit Area

Emergency

E140

QA

Vault/Safe Emergency

E143

ET

Module Trouble--tamper/comms/subst'n (E011)

Emergency

E145

RU

Module Program Error (E014)

Emergency

E150

UA

Misc/No Type

Emergency

E155

BS

Point-Test Fail

Emergency

E300

TA

Main panel Tamper (E001)

Emergency

E301

AT

AC Trouble (E003)

Emergency

E302

YT

Low Battery (E002)

Emergency

E305

RR

Time Lost (E006)

Emergency

E306

LB

Main panel Config Changed (E008)

Emergency

E309

YM

No battery (E002)

Emergency

E320

YP

Main panel Fuse Failure (E010)

Emergency

E330

LU

Main panel Program Error (E009)

Emergency

E333

YC

Security IP Comms Trouble (E016)

Emergency

E350

YS

Report Delayed, dialer comms trouble (E005)

Emergency

E351

LT

Phone Trouble (E004)

Emergency