Save, M001 – Interlogix Monitor XL Advanced Installation Guide User Manual

Page 32

background image

26

Monitor xL™ Advanced Installation Guide

21-3602E rev1.5

M0xx01 Keypad Selections
Note: “xx” represents the module number.
(left to right on keypad screen) Example:

Default Name

Selections

Description

24

(LCD G-ProxII
Keypad)

Module Type
(number)

See Module Selection Numbers below.

0

LCD Keypad Default
Display Mode

0=Rolling time, date/Message
1=Date only
2=future
3=future

0

LCD Keypad Armed
LED Display

0=Arming state always shown
1=Timed
2=future
3=never

(UK ACPO = 1)

0

LCD Keypad Arming
Tone Mode

0=All E/E tones
1=No Exit tone
2=No Entry
3=No E/E Tones

0

LCD Keypad Auto
Disarm All On Silence

0=None
1=silence all User Areas
2=Disarm
3=Silence and disarm

(UK ACPO = 1)

2

LCD Keypad Verify
User Mode

0=None
1=Auto Verify on Silence
2=Manual Verify
3=future

(UK ACPO = 0)

(yes)

LCD Keypad Multi-
Badge Mode

(yes)

(no)

For keypad modules with external
readers only.

Yes = triple badge mode
No = double badge mode

Module Selection Numbers
1 = Map Pod, 2 = Fx LCD, 3 = Other, 4 = V1 Access, 5 = V1 Wireless, 7 = ISM LCD, 8 = ISM Input/Output, 9 = PDC,
10 = *HSC, 11 = Suite Security 8 zone, 12 = TDC, 14 = V2 Access, 15 = Elevator, 16 = Suite Security 2 zone, 17 = V2
Wireless (FA400), 18 = MF-FA Wireless, 19 = ITI SuperBus Wireless, 20 = IPlus, 21 = C2000, 22 = Inova PointMux,
23 = standard Monitor xL LCD, 24 = Monitor xL LCD GProxII (keypad reader), 25 = Monitor xL LCD (external reader),
29 = Monitor xL Input/Output, 32 = Monitor xL Power Supply, 33 = Wireless 868+900, 34 = Smart/Vigil, 35 = Wireless
868+900+(Australia), 36 = 2050 MIL250 9600 baud only, 37 = 2050 DC, 38 = 2050 IO16, 39 = 2050 I32, 40 = 2050
O32.

*

HSC (High Security Communications) is a proprietary communications of CSG Security Inc. and not used in all markets.

24

·

0

·

0

·

0

·

0

·

2

·

Save

? M001

01