Monitor xL™ Advanced Installation Guide
21-3602E rev1.5
S00104 Keypad Selections
(left to right on keypad screen) Example:
Default Name
Selections
Description
00
Confirmed Alarm Time
Out
Time table codes.
(UK ACPO = 18)
0
Maximum Number of
Alarms per Point
Arming State
0 = All, 1 = 1, 2 = 2, 3 = 3 Primarily for
European Users.
(UK ACPO = 3)
0
Menu Navigation
0 = Standard, 1 = Ok-SOFT-3, 2 = Ok-
SOFT-1, 3 = future.
0
LCD Menu Style
0 = Standard, 1 = Ok-SOFT-3, 2 = Ok-
SOFT-1, 3 = future.
0
Unconfirmed Reset
Mode
0 = None, 1 = Follow Confirm Alarm, 2 =
Include Master, 3 = future.
(no)
Confirm Reset Service
(yes)
□
(no)
(UK ACPO = yes)
(no)
Confirm Reset Master
(yes)
□
(no)
(no)
Confirm Reset
Challenged PIN.
(yes)
□
(no)
(no)
Confirm Reset using
Remote
(yes)
□
(no)
S00105 Keypad Selections (left to right on keypad screen)
Default Name
Selections
Description
01100
AC
Reference
Voltage
–
Main panel electrical mains operation.
E.g. 01100 = 110.0 Decivolts
(UK ACPO = 02200)
070
Battery
Size
Amp hours X 10
E.g. display as 7.0
(UK ACPO = 17.0)
0
AC Sync
0=60 Hz, 1=50 Hz, 2=No sync required,
3=DC supply
Synchronization with AC line to maximize internal clock
accuracy. With an unstable AC source, select "2: AC-
No Sync" ('AC failure' will be reported if the frequency
drops below 12.5 Hz). With a DC source, be sure to
disable E003 (AC Trouble) under "Equipment
Settings".
DC supply option will not detect power failure condition
and will not have a time base sync
(UK ACPO = 1)
0
AC
Brownout
Mode
0=None, 1=Local alarm, 2=Alarm+report,
3=Report only
S00106 Keypad Selections (left to right on keypad screen)
Default Name
Selections
Description
001
VBUS Panel Output Base
See: Main Panel Output
Examples: next
What number the outputs that will be used on
the main controller’s VBUS connection will
start at.
001
Paging Output Base
See: Main Panel Output
Examples: next
What number the outputs that will be used on
the paging system will start at.
Also see S005:08, 09
001
Output Base for:
World Wide Modem with 8 output STU
REDCARE interface or 8 output STU
REDCARE interface
STU = Subscriber Terminal Unit
See: Main Panel Output
Examples: next
What number the outputs that will be used
with the main control board output plug in
boards will start at.
(UK ACPO = 003)
00
·
0
·
0
·
0
·
0
·
·
Save S001