Save a001 – Interlogix Monitor XL Advanced Installation Guide User Manual
Page 29
21-3602E rev1.5
Monitor xL™ Advanced Installation Guide
23
A0xx07
Automatic Arming
Note: “xx” represents the area number.
Keypad Selections
(left to right on keypad screen) Example:
Default Name
Selections
Description
01
(Immediate)
Extended Automatic
Arming Delay
1 – 31
(Delay Table)
Safety margin delay before auto
arming begins.
0
Extended Automatic
Arming Mode
0 – 7
0=Disable
1=Arm if Count <= Min, 2=Arm if
Inactive, 3=When Count<=Min OR
Inactive,
4=When Count <= Min AND Inactive,
5,6,7 spare
Automatically arms an area based on
counting users and/or “area activity
monitoring”.
0
Extended Automatic
Arming Warning Level
(Warning level when arming)
0 – 3
0=Ignore,
1=Warn if users possibly left in area at
time of arming,
2=Block manually arming warn for auto
arming, if
usesr left in.
3=Block all types of arming (manu or
auto)
1 = e.g. user count was not least # at
arming.
2 = e.g. by schedules or other automated
arming.
1
Extended Automatic
Arming Level
0 = (Arm to Stay)
1 = (Arm to On)
Effective if “Extended Auto Arm Mode”
has an active setting.
(no)
Extended Automatic
Arming Only if
Schedule Not in Effect
□
(no)
Both in and out of schedule.
(yes)
Extended automatic arming when out
of schedule.
NOTE: These selections apply if
“Extended Auto Arm Mode” is enabled
and there is an area schedule.
A0xx08 Keypad Selections (left to right on keypad screen)
Note: “xx” represents the area number.
Default Name
Selections
Description
00
Activity Timeout
1 – 31
(Delay Table)
0 = Undefined
Time permitted after specific sensors in an area do not
detect any activity and area is e.g. auto armed. Delay re-
starts if activity is detected. Sensor Activity Detection Types:
Entry/Exit, FAP motion sensors, door contacts, “Activity”
Custom Point Types – see Custom Point programming
section, Command Point – see Custom Point programming
section.
(no)
Include E/E Route FAP
(yes)
□
(no)
Whether Entry/Exit Route & Entry/Exit Route FAP sensors
are used to detect area activity.
FAP – False Alarm Preventer point type.
(no)
Include Doors
(yes)
□
(no)
Doors
are used to detect area activity.
(no)
Alarm On No Activity
(yes)
□
(no)
01
·
0
·
0
·
1
·
·········
Save A001
07