beautypg.com

Save a001 – Interlogix Monitor XL Advanced Installation Guide User Manual

Page 29

background image

21-3602E rev1.5

Monitor xL™ Advanced Installation Guide

23

A0xx07

Automatic Arming

Note: “xx” represents the area number.

Keypad Selections
(left to right on keypad screen) Example:


Default Name

Selections

Description

01

(Immediate)

Extended Automatic
Arming Delay

1 – 31
(Delay Table)

Safety margin delay before auto
arming begins.

0

Extended Automatic
Arming Mode

0 – 7
0=Disable
1=Arm if Count <= Min, 2=Arm if
Inactive, 3=When Count<=Min OR
Inactive,
4=When Count <= Min AND Inactive,
5,6,7 spare

Automatically arms an area based on
counting users and/or “area activity
monitoring”.

0

Extended Automatic
Arming Warning Level

(Warning level when arming)

0 – 3
0=Ignore,
1=Warn if users possibly left in area at
time of arming,
2=Block manually arming warn for auto
arming, if
usesr left in.
3=Block all types of arming (manu or
auto)

1 = e.g. user count was not least # at
arming.
2 = e.g. by schedules or other automated
arming.

1

Extended Automatic
Arming Level

0 = (Arm to Stay)
1 = (Arm to On)

Effective if “Extended Auto Arm Mode”
has an active setting.

(no)

Extended Automatic
Arming Only if
Schedule Not in Effect

(no)

Both in and out of schedule.

(yes)

Extended automatic arming when out
of schedule.

NOTE: These selections apply if
“Extended Auto Arm Mode” is enabled
and there is an area schedule.

A0xx08 Keypad Selections (left to right on keypad screen)
Note: “xx” represents the area number.
Default Name

Selections

Description

00

Activity Timeout

1 – 31
(Delay Table)
0 = Undefined

Time permitted after specific sensors in an area do not
detect any activity and area is e.g. auto armed. Delay re-
starts if activity is detected. Sensor Activity Detection Types:
Entry/Exit, FAP motion sensors, door contacts, “Activity”
Custom Point Types – see Custom Point programming
section, Command Point – see Custom Point programming
section.

(no)

Include E/E Route FAP

(yes)

(no)

Whether Entry/Exit Route & Entry/Exit Route FAP sensors
are used to detect area activity.

FAP – False Alarm Preventer point type.

(no)

Include Doors

(yes)

(no)

Doors

are used to detect area activity.

(no)

Alarm On No Activity

(yes)

(no)

01

·

0

·

0

·

1

·

·········