Interlogix Concord 4 REV C Installation Manual User Manual
Concord 4 installation guide, Content, Contact information
P/N 466-2371
• REV C • NOV12
1
Concord 4 Installation Guide
Content
Contact information 1
Description 1
Panel location 2
Power and wire length 2
Mounting the panel 3
Programming 4
Sensor group characteristics 7
Specifications 9
Regulatory information 9
Contact information
For contact information, see www.utcfireandsecurity.com
or www.interlogix.com.
For technical support, toll-free: 888.437.3287 in the US
including Alaska, Hawaii, Puerto Rico, and Canada.
Outside the tool-free area, contact your dealer.
© 2012 UTC Fire & Security Americas Corporation, Inc.
Interlogix is part of UTC Climate Controls & Security, a
unit of United Technologies Corporation. All rights
reserved.
Description
This is the Installation Guide for the following Concord 4
control panel models:
•
600-1021-95R Concord 4 RF
•
600-1022-95R Concord Express V4
•
600-1040 Concord Commercial V4
•
600-1042 Concord Hybrid
This manual provides information for installing a basic
UL Listed Fire and Security System. To modify or use for
other purposes, visit the UTC Fire & Security website for
additional instructions and training.
Table 1 below shows the standard panel capabilities.
Table 1: Panel capabilities
Capabilities
Concord Express v4
Concord 4/Concord
Com mercial v4
Zones
32
96
Partitions
2
6
Bus devices
16
16
User codes
16
230
Table 2 below describes the basic panel (out-of-box)
hardware capabilities for all panels:
Table 2: Panel hardware capabilities
Pow er
Input for an AC step-dow n, plug-in style
transformer.
Auxiliary pow er
output
Output that supplies 9 to 14 VDC w ith up to 1
amp for bus devices and hardw ired detectors,
such as smoke and motion detectors.
Bus A and B
Input and output that provides communication
betw een bus devices and the panel.
Siren driver
Output that can drive an 8-ohm load and provides
intrusion and fire alarm sounds for partition 1 (6
w atts maximum).
Tw o onboard
outputs
Can be used to activate other signaling devices
based on system events. Out 1 is a 9 to 14 VDC
source output, limited to 1.0 amp maximum. Out
2 is an open-collector output, rated up to 14 VDC,
300 mA maximum.
Microphone input
Input used for tw o-way audio w hen used in
conjunction w ith the Interrogator 200 audio
verification module.
Eight supervised
hardw ired zones
Inputs for various hardw ired detectors. Zone 8
can be set up in programming to accept tw o-wire
smoke detectors. It sources 9 to 14 VDC, 90 mA
maximum.
Built-in RF
receiver
Allow s use of up to 96 or 32 319.5 MHz crystal
and/or SAW learn mode w ireless sensors and
touchpads.