beautypg.com

Save, M001 – Interlogix Monitor XL Advanced Installation Guide User Manual

Page 35

background image

21-3602E rev1.5

Monitor xL™ Advanced Installation Guide

29

M0xx07 Keypad Selections Note: “xx” represents the module number.

WARNING: These Access Control features are only available with the addition of the “Feature Expansion Board”.

(left to right on keypad screen) Example:

Pressing the keypad button under 

?

will display the type of module and the module’s input and output ranges.

Default Name

Selections

Description

(no)

Reader Defined

(yes)

(no)

000

Card Lockout Schedule 00 = No scheduled

lockout
01 – 250 Schedule

A schedule to specify when card access will be blocked

0

Enable or Disable
Cards of Type

0 = None
1=Escort Req’d
2 =non-permanent
users. 3 =all users

0

Enable or Disable
Mode

If enabling reader,
see Note *1 .
If disabling reader,
see Note *2 .

Note *1: If enabling reader, 0=enable for 4 hrs, 1=enable for
8hrs, 2=enable for 12 hrs, 3=enable for 24 hrs, 4=enable for
1 week, 5=enable until midnight tonight, 6=enable
permanently, 7=enable until out of schedule according to
schedule 50.
Note *2: If disabling reader, 0=disable card permanently,
1=disable card but set it so that it can be re-enabled later at
an enabling station, 2= disable card permanently and trigger
auxiliary output , 3= disable card enable re-enroll and trigger
auxiliary output, 4 to 7 = not used, same as 1 (room for
future expansion)

(no)

Arming Station or
Keypad Reader
connected to Reader
LCD Keypad

(yes)

(no)

NOTE: Bi-colour LED must be enabled for command station
R0017.

(no)

Lockout In Schedule

(yes)

(no)

Toggles the lockout between inside of the chosen schedule (

), compared to outside of the schedule ( □ ).

(no)

Enabling Reader

(yes)

(no)

·

000

·

0

·

0

·



···

Save

? M001

07