Monitor xL™ Advanced Installation Guide
25
Program Section: G001 (Group Area)
for use with corresponding areas G001 – G016.
G0xx00 Keypad Selections Note: “xx” represents the area number.
(left to right on keypad screen)
Default Name
Selections Description
(no)
Enable Group Area
(yes)
□
(no)
For use with Area Group Mode
S00108
Blank
(12 characters)
Area Group Name
–
G0xx01 Keypad Selections (left to right on keypad screen)
Note: “xx” represents the area number.
Default Name
Selections Description
(no)
All Areas
Area 1 to Area 16
(yes)
□
(no)
Select the areas that will apply to Area Group Mode.
Program Section: M001 (Modules)
M0xx00 Keypad Selections Note: “xx” represents the module number: 01 – 24.
(left to right on keypad screen) Example:
Pressing the keypad button under
?
will display the type of module and the module’s input and output ranges.
Default Name
Selections
Description
00000
Serial Number
00000 - 65535
5 digit # on sticker on module circuit board.
01
Area
01 – 16
Module assigned to which area?
2 Digits 01 – 16 = Area #
2
Inputs
0 = 00, 1 = 04, 2 = 08,
3 = 12, 4 = 16, 5 = 20,
6 = 24, 7 = 32
The number of input points (sensors) supported by the
module.
Default for Area 1: 4, Default for Area 2: 1
1
Outputs
0 = 00, 1 = 04, 2 = 08,
3 = 12, 4 = 16, 5 =
20, 6 = 24, 7 = 32
The number of programmable outputs supported by the
module.
Default for Area 1: 1, Default for Area 2: 1
1
Exit Delay
0 = Never.
1 = When arming to
Stay or On
*2 = Not used
3 = When arming to
On
If the keypad has the Exit delay set to 1, this means that the
keypad would be protected when the area goes into Stay 1,
2 or On. An exit delay occurs and, if Alarm on Fail to Exit is
set in the area configuration, the system must see a door
transition otherwise a Fail to Exit will result. Of course this
would be an internal door whose level is set to 1 or 2 or 3.
If the keypad is outside the protected area, the Exit delay is
set to 0. When arming the area, the UI would not be
affected.
(yes)
Entry/Exit Tones in
Stay
(yes)
□
(no)
Are E/E tones to sound at this (keypad) if a door opened
with area armed to 'Stay'.
(yes)
Monitor Tamper
(yes)
□
(no)
Note:
(yes) if module requires tamper, comms,
substitution detection
(
Definitions): Stay: Perimeter sensors monitored (plus any 24 hr sensors); On: All sensors monitored.
Keypad NOTES
If the keypad module has the Exit delay set to 1, this means that the keypad would be protected when the area goes into Stay
or On. An exit delay occurs and, if Alarm on Fail to Exit is enabled in the Area Program Section: A0xx01, the system must
see a door transition otherwise a Fail to Exit Alarm will result. This would be an Entry/Exit door whose protection level is set to
Stay or On.
If the keypad module is outside the protected area, the Exit delay is set to 0. When arming the area, Alarm on Fail to Exit would
not apply.