Page 21
21-3602E rev1.5
Monitor xL™ Advanced Installation Guide
15
S00507 Keypad Selections (left to right on keypad screen)
Default Name
Selections
Description
000000 SIP Account
SIP = Security IP Receiver
0
HSC Mode
0= NotUsed, 1=SIP1, 2=SIP2, 3=HSC
POD (module)
HSC POD (High Security Communications) is
a proprietary communications of CSG
Security Inc. and not used in all markets.
0
HSC Timeout
0=90sec, 1=3min, 2=5min, 3=10min
0
HSC Full Report By
Area
0=full reporting always, 1=use area
emergency/full setting
0
SIP Baud Rate
0=150, 1=600, 2/3=future
0
HSC SIP Auto Set
0=manual settings, 1=SIP receiver sets all
variables
S00508 Keypad Selections (left to right on keypad screen)
Default Name
Selections
Description
0
Paging Mode 0 = None, 1 = Numeric SemaDigit w/ HS, 2 = Blind
SemaDigit, 3 = SemaPhone,future
Also see S001:06, 07
(no)
Paging
Output Data
(yes)
□
(no)
Also see S001:06, 07
S00509 Keypad Selections (left to right on keypad screen)
Default Name Selections
Description
Blank
(16 characters)
Paging Phone
Number
–
Also see S001:06, 07
Paging phone number the system will dial to transmit reports.
The phone number can be preceded with P =pulse dialing (default), or T =Tone
dialing, and can include D =2 sec Delay, A =Star key (tone dialing), # = Pound Sign
(tone dialing), and/or W = Wait for second dial tone. For Tone dialing, ensure the
phone line supports this.
S00510 Keypad Selections
(left to right on keypad screen) Example:
Default Name
Selections
Description
00000
Main Control Board
Address
(Panel Serial Number)
Up to 5 digits, 0 = Undefined, 1 – 65534 =
Director software connection
, 65535 = Special
Debug Mode
This is the serial number of the main
control board that is automatically
assigned.
0
Main Control Board
Connection Type
For viewing only. These selections are only done
at the Director software and not entered here.
They appear automatically in this selection when
the software first communicates with the main
controller board.
0: Direct-Cable
1: External Modem
2: Internal Modem – Bell 103
3: IP
4:
Future
5: Internal Modem – World Wide
This specifies the type of connection
to a Director software PC.
0
Main Control Board
Reporting Mode
0: No Main Control Board reporting;
1: Blocks of 256 events;
2: Alarms (indiv. / small blocks)
Whether or not alarms or blocks of
events will be auto-transmitted to the
Director software.
Available with Monitor ISM using an
external modem or IP or with Monitor
xL using IP.
0
Main Control Board
Shared phone line
mode
0= Not shared, 1= Preemptive always, 2= User
intervention required w/ time, 3= Timed
0
Main Control Board
BaudRate
0=AutoMin(38K),
1= AutoMax (115K),
2=AutoMin (56K), 3=future
00000
·
0
·
0
·
0
·
0
·
0
·
Save S005
10