Save, M001 – Interlogix Monitor XL Advanced Installation Guide User Manual
Page 33
21-3602E rev1.5
Monitor xL™ Advanced Installation Guide
27
M0xx02 Annunciation Map
Keypad Selections (left to right on keypad screen)
Note: “xx” represents the module number.
Default Name
Selections Description
Area 1 – 16:
(yes)
Area 1 to Area 16
(yes)
□
(no)
AnnuAreaMap defines which areas the module
can alert sirens, sonalerts and other sound
notifications from.
M0xx03 Arm/Disarm Map
Keypad Selections (left to right on keypad screen)
Note: “xx” represents the module number.
Default Name
Selections Description
Area 1 – 16:
(yes)
Area 1 to Area 16
(yes)
□
(no)
Defines which areas can be armed /disarmed from
this e.g. keypad.
Required for Area Group Mode assignments
S00108
M0xx04 Exit Delay Map
Keypad Selections (left to right on keypad screen)
Note: “xx” represents the module number.
Default Name
Selections Description
Area 1 – 16:
(yes)
Area 1 to Area 16
(yes)
□
(no)
Defines which areas also have an exit delay when
the area this keypad is assigned to is armed
M0xx05 Keypad Selections Note: “xx” represents the module number.
WARNING: These Access Control features are only available with the addition of the “Feature Expansion Board”.
(left to right on keypad screen) Example:
Pressing the keypad button under
?
will display the type of module and the module’s point and output ranges.
Default Name
Selections
Description
000
Schedule
0-250
01
Single Badge In-
Schedule Mode
0=None, 1=Auto
logon, 2=Auto arm
ON, 3=Auto Arm
STAY, 4=Auto
Disarm STAY,
5=Auto Disarm OFF,
6=Toggle OFF-STAY,
7=Toggle OFF-ON,
8=Toggle STAY-ON,
9=Extend Exit Delay,
10=Auto Work Late.
(UK ACPO=05)
01
Single Badge Out of
Schedule Mode
Same selections as
“Single Badge In
Schedule Mode”.
(UK ACPO=05)
07
Hold Badge In
Schedule Mode
Same selections as
“Single Badge In
Schedule Mode”.
(UK ACPO=02)
07
Hold Badge Out of
Schedule Mode
Same selections as
“Single Badge In
Schedule Mode”.
(UK ACPO=02)
000
·
01
·
01
·
07
·
07
·
Save
? M001
05