Monitor xL™ Advanced Installation Guide
49
Program Section: T080 (Custom Inputs)
T08000 Keypad Selections
(left to right on keypad screen) Example:
Default Name
Selections
Description
0
Level
0: 24 hr, 1: Stay & On, 3: On Only
When the input will be monitored.
00
Characteristics
See Custom Input Characteristic Types
list.
What the special input will do.
(UK ACPO custom point # 1 = 40, # 2 = 10)
0
Class
0: Fire Class A (Double Loop); 1: Fire;
2: Hold Up; 3: Aux. Alert; 4: Vault /
Safe; 5: Burglary; 6: Supervisory
How the input will report to the Monitoring
Station.
(UK ACPO custom point # 1 = 6, # 2 = 5)
(no) Bypassable
(yes)
□
(no)
Can this input be bypassed?
(no)
Chime
(yes)
□
(no)
Will this input cause keypads to sound
when it is opened? (E.g. entry door)
(no)
Pre-Alarm Warning
(yes)
□
(no)
Will this input supply a warning alert
delay (keypad sounds), so it can be reset
before reporting to the Monitoring Station
Custom Input Characteristic Types
Characteristic Types: 00: Entry/Exit Door; 01: 1 sec(s); 02: 2s; 03: 3s; 04: 5s; 05: 10s; 06: 15s; 07: 20s; 08: 30s; 09: 45s;
10: 60s; 11: 90s; 12: 2 min(m); 13: 3m; 14: 5m; 15: 10m; 16: 15m; 17: 20m; 18: 30m; 19: 45m; 20: 60m; 21: 90m; 22: 2 hr(h); 23:
4h; 24: 6h; 25: 8h; 26: 10h; 27: 12h; 28: 16h; 29: 20h; 30: 1 day; 31: 1 week; 32: garage; 33: E/E route; 35: FAP (6sec/20min); 37:
E/E route FAP; 39: Activity Monitor; 40: Command Point; 41: Arming Keyswitch; 42: Guard Tour Point; 43: Work Late Function.
Entry/Exit Doors: The 'Entry/Exit Door' selection (characteristic
type = 00) is normally used with doors that are monitored, but not
electronically controlled for personnel access. For access-
controlled doors, a dedicated 'Door Contact' input is provided on
the door-control module (which does not need to be set up as an
input point). Readers & doors are set up via R001 - R032.
Also, an E/E door type-of-point cannot be set for a 24-hr
monitoring level (this will 'undefine' the custom point type). As
well, with E/E doors, the custom bypass selection can be applied
to a custom E/E door type to make it bypassable.
Garage Points: The 'garage' selection (type = 32) refers to
garage door sensors. With these inputs, the 'garage' delay setting
will apply (see A0xx:01), and the area can be armed while the
point is tripped (the garage sensor will be armed after the door is
closed).
FAP: (False Alarm Preventor) If a FAP input is not OK longer than
10 seconds, an alarm condition occurs. If a FAP input is triggered
and immediately resets, a 20 minute timer begins. If the same
device is tripped or a different FAP device trips in the same 20
minutes, an alarm occurs.
Activity Monitor: activation informs the system that the area this
point is connected to is still occupied. Used in conjunction with
A0xx:07.
Activity Monitor and Custom Point Type “Level” selections: 0:
24hr: – 24 hr Activity Monitor – activity point always active (ON,
STAY and OFF). 1: Stay & On – Activity Monitor when area OFF,
standard alarm when in STAY and ON. 3: On Only – Activity
Monitor when area OFF & STAY, standard alarm when ON.
Command Point: Command Points are only configurable through
the Director software. WARNING: Never attempt to edit a
Command point name at a keypad or it may fail to operate.
Keyswitch Operation: If the type is set to 41 (Keyswitch), the
'level' setting specifies whether the switch will arm (1), or disarm
(0) the area associated with the specific input point. Furthermore,
if the custom-type is set to "Chime (
)", and the area is set for
"Stay on Fail to Exit", the area will be armed to 'Stay' if no users exit
after turning the switch (not-Ok to Ok).
Conversely, if the custom-type is set to NOT chime (), the "Stay on
Fail to exit" setting will be ignored (the area will fully arm to 'On').
Note: With an arming keyswitch, disarming is typically done through
an LCD keypad.
Guard Tour Points: For an input point to be used in a guard tour, it
requires a custom point type with the 'type' set as 42 (Guard Tour
Point). For this application, the 'class' should be set as "Supervisory",
and the 'level' will typically be set as "24 hr". Also note that, in this
case, any "TX" selections will be ignored (guard-tour point activity is
referenced only by the Director software during the guard tour).
Work Late Function: This custom type can be assigned to e.g. a
motion detector in an area that is off but is in its LCD keypad, closing
time warning, at the last 15 min of its schedule. If this motion detector
is tripped because area occupants are working late, it will delay the
scheduled closing time. To set the Worklate Time Extension for 'work
late' points in an area, refer to A0xx:01 under "A001 - A016 (Areas
and Related Settings)". NOTE: The Custom Type “Level” can only be
set to “Stay & On” or “On” for this point. Setting it for 24hr will result in
repeated alarms. When the area is armed, this pt type converts to a
standard burg point.
Chime: This setting is often used with Entry points/routes (so
persons know that someone has entered the area).
Pre-Alarm Warning: For associated input-points, alarm
transmission (to the central station) will be delayed as per the "Pre-
Alarm Delay" setting (for the specific 'area'). During the delay,
keypad sonalert(s) will be sounded, giving an authorized user time to
"Silence" the alarm at a keypad. (Selecting "Verify User" will cancel
the alarm transmission.)
To set the "Pre-alarm Delay" time for a specific area, refer to A0xx:01
under "A001 - A016 (Areas and Related Settings)". To set the areas
to be monitored by a specific keypad, refer to M0xx:01 under "M001 -
M024 (Modules and Related Settings)".
0
·
00
·
0
·
······
Save T080
00