Save a001 – Interlogix Monitor XL Advanced Installation Guide User Manual
Page 27
21-3602E rev1.5
Monitor xL™ Advanced Installation Guide
21
A0xx03
Area Schedule Selections
Note: “xx” represents the area number.
Keypad Selections
(left to right on keypad screen) Example:
Default Name
Selections
Description
000
Area Schedule
00 = none,
01-250 = schedule #
The schedule used to automate this area and enable
all scheduling features (if applicable).
0
Out of Schedule Open
0=30min, 1= 2-hours
2 = Unlimited
Allowed duration for Disarming outside of schedule.
0
In Schedule Open
0=30min, 1= 2-
hours, 2 = Unlimited
Allowed duration for Disarming within the schedule.
0
Work Late Time
Extension
0=30 min, 1=1hr,
2=1.5hr, 3=2hr,
4=3hr, 5=4hr, 6=6hr,
7=8hr
The duration that the scheduled closing time will be
extended when a work-late button is pressed at an
e.g. area’s keypad.
(no)
Limit to Midnight
(yes)
□
(no)
Limit 'work-late' to not extend beyond midnight.
(no)
Transmit Fail to Close
(yes)
□
(no)
If an area is not armed at the end of its schedule, a fail to
close is transmitted to the monitoring station.
(no)
Auto Arm on Fail to
Close
(yes)
□
(no)
‘Stay-on-fail-to-exit’ and ‘AutoArm-on-fail-to-close’ cannot be
(yes) simultaneously.
(no)
Allow Un-authorized
Open
(yes)
□
(no)
Authority needed to disarm after-hours. Whether or
not users without '24-hr' authority will be able to
disarm this area outside of its open/close schedule,
and/or adjust the area closing time (i.e., 'worklate')
after their schedule has expired. (For a non-
scheduled area, this feature does not apply, since only
'Disarm' authority would be required.)
(no)
Auto Disarm to Off
Always
(yes)
□
(no)
A0xx04 Automation
Keypad Selections (left to right on keypad screen)
Note: “xx” represents the area number.
Default Name
Selections
Description
000
Automatic Stay-Mode
Schedule #
00 = none,
01-250 = schedule #
0
Automatic Stay-Mode
0 = None
1 = Standard ‘Auto Stay Mode’ (Non-
secure)
2 = Secure ‘Auto Stay Mode’
(Requires Area On before next
automatic Stay To Off)
0
Auto Disarm on Valid
Token In Area
Schedule
NOTE: This feature is only
available with the addition of the
Feature Expansion Board.
0 = None, 1= Follow user authority
2 = Force to Stay 3 = Force to Off
The area will automatically disarm
when a user/entrant is granted access
in the area schedule.
0
Auto Disarm on Valid
Token Out of Area
Schedule
NOTE: This feature
is only available with the addition
of the Feature Expansion Board.
0 = None, 1= Follow user authority
2 = Force to Stay, 3 = Force to Off
The area will automatically disarm
when a user/entrant is granted access
out of the area schedule.
000
·
0
·
0
·
0
·
·
Save A001
03