57

The following program sections are only applied using the Director Software and Feature
Expansion Board. Displays in these keypad programming screens are for viewing only.

C001 - C060 (Suite Security LED Keypads)

Suite Security LED keypad modules provide security and monitoring features for up to 60 individual suite units
associated with a specific main panel. 8 Zone suite security LED keypads support 8 monitored sensors/inputs,
2 programmable outputs, and 3 'panic keys'. '2 Zone' LED units support 2 monitored sensors/inputs, one panic
key, and one programmable output.

These "Suite Security" keypads can be set up only through the Director Software (subject to your software
version and licensing agreement). For details, refer to the on-line help or User's Guide for your Director
Software.

Each panel supports all 8 zone or 2 zone or a mixture of both at a maximum of 60 Suite Security LED keypads (with no other
modules). If suite security LED keypads are to be mixed with other modules, the suite security capacity will be reduced by 5 for
each system LCD keypad, and each other expansion / application module that is added. (For example, with 2 system keypads,
3 door controllers, and one point expansion module, a full-capacity "Enterprise" system could still support 30 suite security units).
Suite Security units are not associated with any system 'Areas' or related schedules or settings. All settings that affect suite
security-keypad operation are defined through the "Suite Security" screen of the Director Software. Suite Security LED keypads
are NOT associated with the "Module" screens in any way.
UL / ULC Listed Installations: UL and ULC testing is pending on suite security LED keypads and related features.

V001 - V032 (Elevators/Lifts)

Elevator controller modules provide security and monitoring features for elevator (lift) cabs and associated
floors. These units can be set up only through the Director Software (subject to your software version and
licensing agreement). For details, refer to the on-line help or User's Guide for your Director Software.

Each system can include up to 32 elevators, and a total of up to 124 access-controlled floors. Exception: The elevator capacity
is shared with doors (max. 32 combined). Doors also share the elevator numbering (and panel memory space). Numbers
already defined as doors will not be available for elevators.
With access-controlled elevators, floor call-buttons are disabled until an authorized person presents their access card. When the
card is presented, the specific floors for that person will become available.
UL / ULC Listed Installations: As of this writing, UL and ULC testing is pending on elevator (lift) controllers and related features.

F001 - F124 (Floors)

Systems with elevator controllers can include up to 124 access-controlled floors. These can be in a single
building, or the combined total for multiple buildings. Elevator controllers and floors can be set up only through
the Director Software (subject to your software version and licensing agreement). For details, refer to the on-line
help or User's Guide for your Director Software.

Floors can be set to allow free access during certain times based on a chosen schedule. As well, the status & control feature of
the Director Software allows manually setting floors to allow free access, or apply controlled-access, as desired.
UL / ULC Listed Installations: As of this writing, UL and ULC testing is pending on elevator (lift) controllers and related features.

Condominium