Simon XT Installation Guide

'HVFULSWLRQ

This is the Installation Guide for the Simon XT control panel

(models 600-1054-95R-11 and 600-1054-95R-11-CN).
The system can monitor up to 40 sensors including:

Door/Window sensor (60-670)

Indoor motion sensor (60-639)

Outdoor motion sensor (60-639)

Remote handheld touchpad (60-671)

Two-Way Talking Touchpad/Touch Screen (60-924)

Contact your UTC Fire & Security representative for a more

complete list.

&DXWLRQ

Do not use outdoor motion sensors for intrusion

protection

Table 1 below describes the recommended sensor groups.

7DEOH5HFRPPHQGHGVHQVRUJURXSV
'HYLFH 5HFRPPHQGHG

VHQVRU

JURXS

I

ndoor motion sensor

17

a

Outdoor motion sensor

25 (chime only group)

b

Entry/exit door

10

Interior door

14

Window sensor

13

Smoke sensor

26

c

Key fob

01

ELM key fob

01

Remote handheld touchpad

01

Two-Way Talking Touchpad/Touch

Screen

01

b

CO alarm

34

b

Freeze sensor

29

b

Water sensor

38

b

Personal help button

01

Property/asset management

43

b d

a. Not certified as a primary protection circuit for UL-listed

systems and is for supplementary use only.

b. Has not been investigated by UL.

c. Required for UL-listed residential fire alarm applications.

d. We recommend you use this group type in combination

with a Two-Way Talking Touch Screen.

1RWH

Additional devices employing UTCFS 80 Bit Enhanced

Protocol have not been investigated for use in a UL Listed

installation.

,QVWDOODWLRQ

Tabs at the top of the panel secure and release the front cover

and the chassis. The plastic hinges on the panel bottom allow the

cover and chassis to swing down and out of the way.

7RPRXQWWKHSDQHORQDZDOO

1. Choose a panel location.
2. Run all necessary power, phone, siren, and hardwired

contact wires to the desired panel location.
When choosing the AC outlet location for the AC power

transformer, make sure the outlet is not controlled by a

switch or that it is not part of a ground fault circuit interrupt

(GFCI).

3. Hold the panel against the wall and mark the mounting hole

locations with a pencil.

4. Mount the back piece to the wall through the two horizontally

centered mounting holes near the top and bottom using the

supplied mounting hardware. Use wall anchors if no studs are

present.

&RQQHFWLQJKDUGZLUHGGHYLFHV

The panel has five screw terminals, two battery terminals, and

two telephone connections. The screw terminals connect the AC

power, sirens, and or hardwired detectors.

)LJXUH:LULQJWHUPLQDOV

HW

1 I/O

HW1

&

2

D

C

out

HW2

in

9V

A

C

i

n

9V

A

C

i

n

B

a

tter

y

+

B

a

tter

y

-

Program sensors and devices before you install them. Follow the

instructions in “Sensors” on page 4 to add the sensors to panel

memory.
The HW1 I/O terminal is dual purpose and can be used for either

siren or hardwired contact connections. The HW2 in terminal is an

input only.

,QWHULRUVLUHQV

From the factory, the HW1 I/O input (terminal 1) is set up for

interior siren operation (status and alarm sounds). The HW1&2 DC

out (terminal 2) provides the positive (+) voltage.

© 2011 UTC Fire & Security. All rights reserved.

1 / 8