Tcp/ip, Ft-10, Thernet – Flintec FT-10xx User Manual
Page 66: Only, ] ethernet
![background image](/manuals/676078/66/background.png)
FT-10 Smart Process Indicator, Technical Manual, Rev. 1.0, January 2014
11.
E
THERNET
TCP/IP
(
ONLY
FT-10
EN
)
Ethernet output of FT-10 EN is programmable to BSI command set, Continuous data output, Fast continuous
data output, Modbus TCP/IP High-Low, Modbus TCP/IP Low-High.
The first three data structures can be find in the related sections indicated in the table below.
You can find below the difference of Low-High and High-Low data formats and some companies using these
formats.
Data Format
Description
Company samples
BSI Command set
Refer to Page 40
Continuous
Refer to Page 40
-
Fast Continuous
Refer to Page 40
-
Modbus TCP High-Low
Modbus TCP interfacing.
Refer to Page 67.
Interfacing with PLC.
Modbus TCP Low-High
Modbus TCP interfacing.
Refer to Page 67.
Interfacing with PLC.
Table 11.1 - Ethernet output interfacing
[03-] Ethernet
This sub-block includes the parameters related with the Ethernet of FT-10 indicator.
[030 4 ] Data Format
0 : No data transfer.
1 : Continuous data output
( Page 39 )
2 : Print mode
( Parameter [ 040 ] on Page 26 )
3 : BSI command set
( Page 40 )
4 : Modbus TCP High-Low
( Page 67 )
5 : Modbus TCP Low-High
( Page 67 )
6 : Fast continuous mode
( Page 40 )
[031 01] Device Address
The address of FT-10 will be entered between 01 to 255.
[032 ] IP Address
The IP address will be entered as ” aaa.bbb.ccc.ddd ”. Default: “192.168.16.250”.
For changing the IP address, press the < Tare
> key and enter the first 3 “a” digits of the IP address.
Press < Enter
> key to access the following “b”, “c” and “d” address entries.
Press the <
> key to access the next parameter.
[033 ] Subnet Mask Address
The IP address will be entered as ” aaa.bbb.ccc.ddd ”. Default: “255.255.255.000”.
For changing the IP address, press the < Tare
> key and enter the first 3 “a” digits of the IP address.
Press < Enter
> key to access the following “b”, “c” and “d” address entries.
Press the <
> key to access the next parameter.
[034 ] Gateway Address
The IP address will be entered as ” aaa.bbb.ccc.ddd ”. Default: “192.168.16.253”.
For changing the IP address, press the < Tare >
key and enter the first 3 “a” digits of the IP address.
Press < Enter
> key to access the following “b”, “c” and “d” address entries.
Press the <
> key to access the next parameter.
[035 ] Local Port
The local port will be entered between 00001 to 65535. Default:
“502”.