FT-10 Smart Process Indicator, Technical Manual, Rev. 1.0, January 2014
FT-10 EN Ethernet
Communication
Transmission rate
10 Mbit/s, half duplex
TCP/IP settings
Manual IP assign over EtherX PC Software
Installation
Switched Ethernet transmission with shielded twisted pair cables and RJ-45
connectors.
Web client
Available
Response speed
Up to 4 ms response delay after read/write commands
FT-10 CO CANopen
Communication
Data rate
10 kbit/s
– 1 Mbit/s (selectable) kbit/s
ESD file
Generic EDS-file provided
Topology
Line with Trunkline, Dropline structure and Termination at both Ends
Line length depending on baudrate 25
– 500 meter.
Installation
2 wire shielded twisted pair cable
Alternatively 4 wire with 24 Volt power over the bus
Max. Stations
Up to 127 stations per network
Isolation
Galvonically isolated bus electronics
Response speed
Up to 4 ms response delay after read/write commands
3.4 The Front View and Key Functions
Figure 3.1 - Front panel view of FT-10
3.4.1 Display
The weight display of FT-10
is seven segments LED. At the right side of the display there are two LED’s for
indicating the net and the unit ( standard kg ), also the left side of the display for indicating the gross, center
of zero and unstable.