FT-10 Smart Process Indicator, Technical Manual, Rev. 1.0, January 2014
[03-] Ethernet (Only FT-10 EN)
This sub-block includes the parameters related with the Ethernet of FT-10 indicator.
[030 4 ] Data Format
0 : No data transfer.
1 : Continuous data output
( Page 39 )
2 : Print mode
( Parameter [ 040 ] on Page 26 )
3 : BSI command set
( Page 40 )
4 : Modbus TCP High-Low
( Page 67 )
5 : Modbus TCP Low-High
( Page 67 )
6 : Fast continuous mode
( Page 40 )
[031 01] Device Address
The address of FT-10 will be entered between 01 to 255.
[032 ] IP Address
The IP address will be entered as ” aaa.bbb.ccc.ddd ”. Default is “192.168.16.250”.
For changing the IP address, press the < Tare
> key and enter the first 3 “a” digits of the IP address.
Press < Enter
> key to access the following “b”, “c” and “d” address entries.
Press the <
> key to access the next parameter.
[033 ] Subnet Mask Address
The IP address will be entered as ” aaa.bbb.ccc.ddd ”. Default is “255.255.255.000”.
For changing the IP address, press the < Tare
> key and enter the first 3 “a” digits of the IP address.
Press < Enter
> key to access the following “b”, “c” and “d” address entries.
Press the <
> key to access the next parameter.
[034 ] Gateway Address
The IP address will be entered as ” aaa.bbb.ccc.ddd ”. Default is “192.168.16.253”.
For changing the IP address, press the < Tare
> key and enter the first 3 “a” digits of the IP address.
Press < Enter
> key to access the following “b”, “c” and “d” address entries.
Press the <
> key to access the next parameter.
[035 ] Local Port
The local port will be entered between 00001 to 65535. Default
is “502”.
[036 0] Response Speed
0 : Modbus TCP Answer is sent immediately after Request is received.
1 : Modbus TCP Answer is delayed 20 msec after Request is received.
2 : Modbus TCP Answer is delayed 50 msec after Request is received.
This property is very helpful for slow PLC systems
[04-] Printer
If one of the serial interfaces is selected as printer, the label settings will be made in his sub-block.
[040 2 ] Print Out Format
1 : Single line
( Page 40 )
2 : Multi line-1
( Page 40 )
2 : Multi line-2
( Page 40 )
[041 1] CN ( Consecutive Number )
0 : The “Consecutive Number” will not be located on the printout.
1 : The “Consecutive Number” will be located on the printout.
[042 ] Minimum Print
[ XXXXXX] If the weight is less than the value entered here, the data will not be printed.