1 analogue output block [4--] ( only ft-10 an ), ] signal selection, ] zero adjustment – Flintec FT-10xx User Manual
Page 36: ] span adjustment
![background image](/manuals/676078/36/background.png)
FT-10 Smart Process Indicator, Technical Manual, Rev. 1.0, January 2014
5.5.1 Analogue Output Block [4--] ( Only FT-10 AN )
The calibration of the analogue output is performed in this sub-block.
[40-] Signal Selection
[400 0] Analogue Output Mode
0 : 4
– 20 mA
1 : 0
– 20 mA
2 : 0
– 5 VDC
3 : 0
– 10 VDC
[401]
Set Analogue Output to calibration range
Press Enter key. [ Ld dEf ] message appears on the display. Press
key for loading default
values or press
key to go next sub block.
[41-] Zero Adjustment
[410]
Coarse Zero Adjustment
The coarse zero adjustment is being performed by pressing
key one after another to increase
the analogue signal level or
key to decrease the analogue signal level.
[411]
Fine Zero Adjustment
The fine zero adjustment is being performed by pressing
key continuously one after another
to increase the analogue signal level or
key to decrease the analogue signal level.
[42-] Span Adjustment
[420]
Coarse Span Adjustment
Coarse span adjustment is being performed by pressing
key continuously one after another to
increase the analogue signal level or
key to decrease the analogue signal level by taking the
full capacity value as reference without placing any weight.
[421]
Fine Span Adjustment
Fine span adjustment is being performed by pressing
key one after another to
increase the analogue signal level or
key to decrease the analogue signal level by
taking the full capacity value as reference without placing any weight