Flintec FT-10xx User Manual
Page 62
FT-10 Smart Process Indicator, Technical Manual, Rev. 1.0, January 2014
Bit Number
2
nd
Dword Description
D31 … D24
Outputs
Output bit status ( Active = 1 )
D23 … D16
Inputs
Input bit status ( Active = 1 )
D15 … D12
Error Codes
of FT-10 PN
Bin
Dec
0000
0
No error found
0001
1
ADC out
0010
2
ADC over
0011
3
ADC under
0100
4
System Error
0101
5
In programming mode
0110
6
Low/High Voltage Error
D11 … D9
Not in use
D8
Zero Range
0
Weight is in zero range
1
Weight is out of zero range
D7
Indication
0
Gross
1
Net
D6
MD
– Motion
Detection
0
Stable
1
Dynamic
D5 … D1
D5 … D1
Read
Command
Response
Read
Command
Response
(continuation
of previous
page)
00000
0
Indicated weight
00001
1
Gross weight
00010
2
Tare weight
00011
3
Calibration Status (Refer to Table 10.1 )
00100
01110
4
14
Not used
01111
15
Set Point-1 Low
10000
16
Set Point-1 High
10001
17
Set Point-2 Low
10010
18
Set Point-2 High
10011
19
Set Point-3 Low
10100
20
Set Point-3 High
10101
21
Set Point-4 Low
10110
22
Set Point-4 High
10111
23
Set Point-5 Low
11000
24
Set Point-5 High
11111
31
Use the Expanded Command list ( Refer to Table
10.2)
D0
CMD Flag
Toggles
The command is applied successfully