beautypg.com

EVCO EPV4CBR Hardware manual User Manual

Page 27

background image

EVCO S.p.A.

Vcolor | Hardware manual ver. 1.0 | Code 144VCOE104

page 27 of 38

Beep Mode

0

2

- - -

2

kind of beep when pressing a sensitive area of the display of the

device

0 =

no

beep

1 =

always

2

= on condition the area is sensitive

Print Frame

0

1

- - -

0

showing frames instead small size pages

1 =

yes

7.7.4

Configuration parameters of the submenu “CAN bus” of the menu “Networks”

The following table shows the meaning of the configuration parameters of the section “CAN Network” of the submenu “CAN bus” of the

menu “Networks”.

PARAM.

MIN.

MAX.

U.M.

DEF.

DESCRIPTION

MyNode

1

127

- - -

99

local CAN node address, or of the device

Master

- - -

- - -

- - -

YES

the device always works as master

Baud

- - -

- - -

- - -

Auto

baud rate of the CAN communication

20K =

20,000

baud

50K =

50,000

baud

125K =

125,000

baud

500K =

500,000

baud

Auto

= the device automatically detects the baud rate of

the other elements of the networ, on condition

that it is one of those listed here above; on

afterwards set the baud rate to the same value of

the other elements

Timeout 1 240 s

5

time-out of the remote CAN communication, or with the other

elements of the network (once the time you have set with this

parameter has elapsed without CAN communication with an

element, this is disabled)

Network

Node

[1] 1

[32] 127

- - -

- - -

remote CAN nodes address, or of the other elements of the

network (example for [1] 2)

[1] = node

2 = node

address