EVCO EVB1256N9D User Manual
Page 63
EVCO S.p.A.
EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134
page 63 of 92
i8
0
15
- - - -
0
0
0
0
0
0
0
0
number of multifunction input alarms (code “iA”) such to
cause a pressure switch alarm (code “iSd”) (only if i5
and/or i15 = 3)
0
= function disabled
i9
1
999
min
240
240
240
240
240
240
240
240
time that must pass in absence of multifunction input
alarms (code “iA”) so that the alarm counter is reset (only
i5 and/or i15 = 3)
i10
0
999
min
0
0
0
0
0
0
0
0
time that must pass in absence of door micro switch input
activations (after the room temperature or COT
temperature has reached the working set-point) for the
“energy saving” function to be activated (this impacts the
evaporator fan only if F0 = 1, 2, 3 or 4); see also r4, HE2
and H01... H14
0
=
the function will never be activated due to the
effect of this condition
i13
0
240
- - - -
180
180
180
180
180
180
180
180
number of door switch input activations such as to
provoke the defrost activation
0
=
defrosting will never be activated due to the effect
of this condition
i14
0
240
- - - -
32
32
32
32
32
32
32
32
minimum duration of the door switch input activation such
as to provoke the defrost activation
0
=
defrosting will never be activated due to the effect
of this condition