EVCO EVB1256N9D User Manual
Page 49

EVCO S.p.A.
EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134
page 49 of 92
PARAM.
MIN.
MAX.
M.U.
E
V
B
1
2
0
4
E
V
B
1
2
1
4
E
V
B
1
2
0
6
E
V
B
1
2
1
6
E
V
B
1
2
2
6
E
V
B
1
2
3
6
E
V
B
1
2
4
6
E
V
B
1
2
5
6
DEFROSTING
d0
0
99
h
8
8
8
8
8
8
8
8
if d8 = 0, 1 or 2, defrosting interval (13)
0
=
interval defrosting will never be activated
d8 = 3, maximum defrost interval
d1
0
2
- - - -
0
0
0
0
0
0
0
0
type of defrosting
0
=
ELECTRIC - during defrosting the compressor will
remain off and the defrosting output will be
activated; evaporator fan activity will depend on
parameter F2
1
=
BY HOT GAS - during defrosting the compressor
will be switched on and the defrosting output will
be activated; evaporator fan activity will depend
on parameter F2
2
=
VIA STOPPING OF COMPRESSOR - during
defrosting the compressor will remain switched off
and the defrosting output will remain deactivated;
evaporator fan activity will depend on parameter
F2
d2
-99
99.0
°C/°F
(1)
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
temperature at end of defrosting (only if P3 = 1); see also
d3
d3
0
99
min
30
30
30
30
30
30
30
30
if P3 = 0 o 2, defrosting duration
se P3 = 1, maximum defrosting duration; see also d2
0
=