beautypg.com

EVCO EVB1256N9D User Manual

Page 54

background image

EVCO S.p.A.

EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134

page 54 of 92

PARAM.

MIN.

MAX.

M.U.

E

V

B

1

2

0

4

E

V

B

1

2

1

4

E

V

B

1

2

0

6

E

V

B

1

2

1

6

E

V

B

1

2

2

6

E

V

B

1

2

3

6

E

V

B

1

2

4

6

E

V

B

1

2

5

6

TEMPERATURE ALARMS

A0

0

1

- - - -

0

0

0

0

0

0

0

0

temperature associated with the minimum temperature

alarm (code “AL”)

0

=

room temperature or CPT temperature

1

=

evaporator temperature (20)

A1

-99.0

99.0

°C/°F

(1)

-10.0

-10.0

-10.0

-10.0

-10.0

-10.0

-10.0

-10.0

temperature

below

that

at

which

the

minimum

temperature alarm is activated (code “AL”); see also A0,

A2 and A11

A2

0

2

- - - -

1

1

1

1

1

1

1

1

type of minimum temperature alarm (code “AL”)

0

=

alarm absent

1

=

relative to working set-point (that is “working set-

point - A1”; consider A1 without sign)

2

=

absolute (that is A1)

A4

-99.0

99.0

°C/°F

(1)

10.0

10.0

10.0

10.0

10.0

10.0

10.0

10.0

temperature higher than that at which the maximum

temperature alarm is activated (code “AH”); see also A5

and A11

A5

0

2

- - - -

1

1

1

1

1

1

1

1

type of maximum temperature alarm (code “AH”)

0

=

alarm absent

1

=

relative to working set-point (that is “working set-

point + A4”; consider A1 without sign)

2

=

absolute (that is A4)

A6

0

240

min

120

120

120

120

120

120

120

120

delay in maximum temperature alarm (code “AH”) after

the device is switched on (8)