EVCO EVB1256N9D User Manual
Page 54
EVCO S.p.A.
EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134
page 54 of 92
PARAM.
MIN.
MAX.
M.U.
E
V
B
1
2
0
4
E
V
B
1
2
1
4
E
V
B
1
2
0
6
E
V
B
1
2
1
6
E
V
B
1
2
2
6
E
V
B
1
2
3
6
E
V
B
1
2
4
6
E
V
B
1
2
5
6
TEMPERATURE ALARMS
A0
0
1
- - - -
0
0
0
0
0
0
0
0
temperature associated with the minimum temperature
alarm (code “AL”)
0
=
room temperature or CPT temperature
1
=
evaporator temperature (20)
A1
-99.0
99.0
°C/°F
(1)
-10.0
-10.0
-10.0
-10.0
-10.0
-10.0
-10.0
-10.0
temperature
below
that
at
which
the
minimum
temperature alarm is activated (code “AL”); see also A0,
A2 and A11
A2
0
2
- - - -
1
1
1
1
1
1
1
1
type of minimum temperature alarm (code “AL”)
0
=
alarm absent
1
=
relative to working set-point (that is “working set-
point - A1”; consider A1 without sign)
2
=
absolute (that is A1)
A4
-99.0
99.0
°C/°F
(1)
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
temperature higher than that at which the maximum
temperature alarm is activated (code “AH”); see also A5
and A11
A5
0
2
- - - -
1
1
1
1
1
1
1
1
type of maximum temperature alarm (code “AH”)
0
=
alarm absent
1
=
relative to working set-point (that is “working set-
point + A4”; consider A1 without sign)
2
=
absolute (that is A4)
A6
0
240
min
120
120
120
120
120
120
120
120
delay in maximum temperature alarm (code “AH”) after
the device is switched on (8)