EVCO EVB1256N9D User Manual
Page 56

EVCO S.p.A.
EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134
page 56 of 92
PARAM.
MIN.
MAX.
M.U.
E
V
B
1
2
0
4
E
V
B
1
2
1
4
E
V
B
1
2
0
6
E
V
B
1
2
1
6
E
V
B
1
2
2
6
E
V
B
1
2
3
6
E
V
B
1
2
4
6
E
V
B
1
2
5
6
EVAPORATOR FAN AND CONDENSER FAN
F0
0
5
- - - -
1
1
1
1
1
1
1
1
evaporator fan activity during normal operation
0
=
switched off
1
=
switched on; see also F13, F14 and i10 (23)
2
=
in parallel with the compressor; see also F9, F13,
F14 and i10 (24)
3
=
depending on F1; see also F9, F13, F14 and i10
(25) (26)
4
=
switched off if the compressor is switched off,
dependent on F1 if the compressor is switched on;
see also F9, F13, F14 and i10 (25) (27)
5
=
depending on F6; see also F9
F1
-99.0
99.0
°C/°F
(1)
-1.0
-1.0
-1.0
-1.0
-1.0
-1.0
-1.0
-1.0
evaporator temperature above the limit at which the
evaporator fan is switched off (only if F0 = 3 o 4); see
also F8
F2
0
2
- - - -
0
0
0
0
0
0
0
0
evaporator fan activity during defrosting and dripping
0
=
switched off
1
=
switched on (setting parameter d7 to 0 is
recommended)
2
=
depending on F0