EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134

page 56 of 92

PARAM.

MIN.

MAX.

M.U.

E

V

B

1

2

0

4

E

V

B

1

2

1

4

E

V

B

1

2

0

6

E

V

B

1

2

1

6

E

V

B

1

2

2

6

E

V

B

1

2

3

6

E

V

B

1

2

4

6

E

V

B

1

2

5

6

EVAPORATOR FAN AND CONDENSER FAN

F0

0

5

- - - -

1

1

1

1

1

1

1

1

evaporator fan activity during normal operation

0

=

switched off

1

=

switched on; see also F13, F14 and i10 (23)

2

=

in parallel with the compressor; see also F9, F13,

F14 and i10 (24)

3

=

depending on F1; see also F9, F13, F14 and i10

(25) (26)

4

=

switched off if the compressor is switched off,

dependent on F1 if the compressor is switched on;

see also F9, F13, F14 and i10 (25) (27)

5

=

depending on F6; see also F9

F1

-99.0

99.0

°C/°F

(1)

-1.0

-1.0

-1.0

-1.0

-1.0

-1.0

-1.0

-1.0

evaporator temperature above the limit at which the

evaporator fan is switched off (only if F0 = 3 o 4); see

also F8

F2

0

2

- - - -

0

0

0

0

0

0

0

0

evaporator fan activity during defrosting and dripping

0

=

switched off

1

=

switched on (setting parameter d7 to 0 is

recommended)

2

=

depending on F0