EVCO EVB1256N9D User Manual
Page 33
EVCO S.p.A.
EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134
page 33 of 92
10.2
Display
of
HACCP
alarm
information
To begin the procedure:
1.
Make sure that the keyboard is not locked and that
no procedure is in progress.
2.
Hold the key “DOWN” for 1 s: the display will show
the first label available.
3.
Press and release the "UP" or "DOWN" key to
select “LS”.
4.
Press and release the “SET” key:
4.1
in the models without a clock the
display will show one of the codes
included in the table in paragraph
“Preliminary notes”
4.2
in the models with a clock the display
will show one of the codes included in
the table in paragraph “Preliminary
notes” followed by a number; the
higher the number, the less current
the alarm.
If the device does not have any alarms stored, the label “LS”
will not be displayed.
To select an alarm:
5.
Press and release the “UP” key or the “DOWN”
key.
To see information regarding the alarm:
6.
Press and release the “SET”
key: the HACCP LED
will stop flashing and remain on permanently and
the display will show, for example, the following
information in succession:
INFORM.
MEANING
8.0
the critical value is 8.0 °C/8 °F
StA
the display is about to show the date and time
at which the alarm occurs (only in the models
with clock)
y14
the alarm occurred in 2014 (continue...)
n03
the alarm occurred in the month of March
(continue...)
d26
the alarm occurred
on 26 March 2014
(continue...)
h16
the alarm occurred at 16:00 (continue...)
n30
the alarm occurred at 16:30
Access the procedure to display information on the HACCP alarms
Selection of information on the HACCP alarms
Display of information on the HACCP alarms