beautypg.com

EVCO EVB1256N9D User Manual

Page 52

background image

EVCO S.p.A.

EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134

page 52 of 92

d15

0

99

min

0

0

0

0

0

0

0

0

minimum time that the compressor must be switched on

before defrosting can be activated (only if d1 = 1) (18)

d16

0

99

min

0

0

0

0

0

0

0

0

predripping duration (during predripping the compressor

will remain switched off, the defrosting output will be

activated and the evaporator fan will remain switched off)

d18

0

999

min

40

40

40

40

40

40

40

40

defrosting interval (only if d8 = 3; defrosting will be

activated when the compressor has been on totally, with

the evaporator temperature below that of d22, for time

d18)

0

=

defrosting will never be activated due to the effect

of this condition

d19

0.0

40.0

°C/°F

(1)

3.0

3.0

3.0

3.0

3.0

3.0

3.0

3.0

evaporator temperature above which the defrost is

activated (relative to the evaporator temperatures

average, or “evaporator temperatures average - d19”)

(only if d8 = 3)

d20

0

500

min

180

180

180

180

180

180

180

180

minimum consecutive time the compressor must be

switched on such as to provoke the defrost activation

0

=

defrosting will never be activated due to the effect

of this condition

This manual is related to the following products: